TY - JOUR
T1 - Biomechanical studies
T2 - Science (f)or common sense?
AU - Science of Variation Group
AU - Mellema, J.J.
AU - Doornberg, J.N.
AU - Guitton, T.G.
AU - Ring, D.
AU - Van Der Zwan, A.L.
AU - Spoor, A.B.
AU - Van Vugt, A.B.
AU - Armstrong, A.D.
AU - Shrivastava, A.
AU - Wahegaonkar, A.L.
AU - Shafritz, A.B.
AU - Adams, J.
AU - Ilyas, A.
AU - Vochteloo, A.J.H.
AU - Castillo, A.P.
AU - Basak, A.
AU - Andreas, P.
AU - Barquet, A.
AU - Kristan, A.
AU - Berner, A.
AU - Ranade, A.B.
AU - Ashish, S.
AU - Terrono, A.L.
AU - Jubel, A.
AU - Frieman, B.
AU - Bamberger, H.B.
AU - Van Den Bekerom, M.P.J.
AU - Belangero, W.D.
AU - Hearon, B.F.
AU - Boler, J.M.
AU - Walter, F.L.
AU - Boyer, M.
AU - Wills, B.P.D.
AU - Broekhuyse, H.
AU - Buckley, R.
AU - Watkins, B.
AU - Sears, B.W.
AU - Calfee, R.P.
AU - Ekholm, C.
AU - Fernandes, C.H.
AU - Swigart, C.
AU - Cassidy, C.
AU - Wilson, C.J.
AU - Bainbridge, L.C.
AU - Wilson, C.
AU - Jones, C.M.
AU - Cornell, C.
AU - Crist, B.D.
AU - Van Deurzen, D.F.P.
AU - Gaston, R.G.
AU - AUTHOR GROUP
AU - Eygendaal, D.
AU - Goslings, J. C.
AU - Schep, N.
AU - Kloen, P.
AU - Haverlag, R.
PY - 2014
Y1 - 2014
N2 - © 2014 Elsevier Ltd. All rights reserved.Introduction: It is our impression that many biomechanical studies invest substantial resources studying the obvious: that more and larger metal is stronger. The purpose of this study is to evaluate if a subset of biomechanical studies comparing fixation constructs just document common sense. Methods: Using a web-based survey, 274 orthopaedic surgeons and 81 medical students predicted the results of 11 biomechanical studies comparing fracture fixation constructs (selected based on the authors' sense that the answer was obvious prior to performing the study). Sensitivity, specificity, and accuracy were calculated according to standard formulas. The agreement among the observers was calculated by using a multirater kappa, described by Siegel and Castellan. Results: The accuracy of predicting outcomes was 80% or greater for 10 of 11 studies. Accuracy was not influenced by level of experience (i.e., time in practice and medical students vs. surgeons). There were substantial differences in accuracy between observers from different regions. The overall categorical rating of inter-observer reliability according to Landis and Koch was moderate (k = 0.55; standard error (SE) = 0.01). Conclusion: The results of a subset of biomechanical studies comparing fracture fixation constructs can be predicted prior to doing the study. As these studies are time and resource intensive, one criterion for proceeding with a biomechanical study should be that the answer is not simply a matter of common sense.
AB - © 2014 Elsevier Ltd. All rights reserved.Introduction: It is our impression that many biomechanical studies invest substantial resources studying the obvious: that more and larger metal is stronger. The purpose of this study is to evaluate if a subset of biomechanical studies comparing fixation constructs just document common sense. Methods: Using a web-based survey, 274 orthopaedic surgeons and 81 medical students predicted the results of 11 biomechanical studies comparing fracture fixation constructs (selected based on the authors' sense that the answer was obvious prior to performing the study). Sensitivity, specificity, and accuracy were calculated according to standard formulas. The agreement among the observers was calculated by using a multirater kappa, described by Siegel and Castellan. Results: The accuracy of predicting outcomes was 80% or greater for 10 of 11 studies. Accuracy was not influenced by level of experience (i.e., time in practice and medical students vs. surgeons). There were substantial differences in accuracy between observers from different regions. The overall categorical rating of inter-observer reliability according to Landis and Koch was moderate (k = 0.55; standard error (SE) = 0.01). Conclusion: The results of a subset of biomechanical studies comparing fracture fixation constructs can be predicted prior to doing the study. As these studies are time and resource intensive, one criterion for proceeding with a biomechanical study should be that the answer is not simply a matter of common sense.
U2 - https://doi.org/10.1016/j.injury.2014.09.014
DO - https://doi.org/10.1016/j.injury.2014.09.014
M3 - Article
C2 - 25306381
SN - 0020-1383
VL - 45
SP - 2035
EP - 2039
JO - Injury
JF - Injury
IS - 12
ER -