T1 - Dynamic contrast-enhanced ultrasound parametric imaging for the detection of prostate cancer
AU - Postema, Arnoud W.
AU - Frinking, Peter J. A.
AU - Smeenge, Martijn
AU - de Reijke, Theo M.
AU - de La Rosette, Jean J. M. C. H.
AU - Tranquart, Francois
AU - Wijkstra, Hessel
PY - 2016
Y1 - 2016
N2 - Objective To investigate the value of dynamic contrast-enhanced (DCE)-ultrasonography (US) and software-generated parametric maps in predicting biopsy outcome and their potential to reduce the amount of negative biopsy cores. Materials and Methods For 651 prostate biopsy locations (82 consecutive patients) we correlated the interpretation of DCE-US recordings with and without parametric maps with biopsy results. The parametric maps were generated by software which extracts perfusion parameters that differentiate benign from malignant tissue from DCE-US recordings. We performed a stringent analysis (all tumours) and a clinical analysis (clinically significant tumours). We calculated the potential reduction in biopsies (benign on imaging) and the resultant missed positive biopsies (false-negatives). Additionally, we evaluated the performance in terms of sensitivity, specificity negative predictive value (NPV) and positive predictive value (PPV) on a per-prostate level. Results Based on DCE-US, 470/651 (72.2%) of biopsy locations appeared benign, resulting in 40 false-negatives (8.5%), considering clinically significant tumours only. Including parametric maps, 411/651 (63.1%) of the biopsy locations appeared benign, resulting in 23 false-negatives (5.6%). In the per-prostate clinical analysis, DCE-US classified 38/82 prostates as benign, missing eight diagnoses. Including parametric maps, 31/82 prostates appeared benign, missing three diagnoses. Sensitivity, specificity, PPV and NPV were 73, 58, 50 and 79%, respectively, for DCE-US alone and 91, 56, 57 and 90%, respectively, with parametric maps. Conclusion The interpretation of DCE-US with parametric maps allows good prediction of biopsy outcome. A two-thirds reduction in biopsy cores seems feasible with only a modest decrease in cancer diagnosis
AB - Objective To investigate the value of dynamic contrast-enhanced (DCE)-ultrasonography (US) and software-generated parametric maps in predicting biopsy outcome and their potential to reduce the amount of negative biopsy cores. Materials and Methods For 651 prostate biopsy locations (82 consecutive patients) we correlated the interpretation of DCE-US recordings with and without parametric maps with biopsy results. The parametric maps were generated by software which extracts perfusion parameters that differentiate benign from malignant tissue from DCE-US recordings. We performed a stringent analysis (all tumours) and a clinical analysis (clinically significant tumours). We calculated the potential reduction in biopsies (benign on imaging) and the resultant missed positive biopsies (false-negatives). Additionally, we evaluated the performance in terms of sensitivity, specificity negative predictive value (NPV) and positive predictive value (PPV) on a per-prostate level. Results Based on DCE-US, 470/651 (72.2%) of biopsy locations appeared benign, resulting in 40 false-negatives (8.5%), considering clinically significant tumours only. Including parametric maps, 411/651 (63.1%) of the biopsy locations appeared benign, resulting in 23 false-negatives (5.6%). In the per-prostate clinical analysis, DCE-US classified 38/82 prostates as benign, missing eight diagnoses. Including parametric maps, 31/82 prostates appeared benign, missing three diagnoses. Sensitivity, specificity, PPV and NPV were 73, 58, 50 and 79%, respectively, for DCE-US alone and 91, 56, 57 and 90%, respectively, with parametric maps. Conclusion The interpretation of DCE-US with parametric maps allows good prediction of biopsy outcome. A two-thirds reduction in biopsy cores seems feasible with only a modest decrease in cancer diagnosis
U2 - https://doi.org/10.1111/bju.13116
DO - https://doi.org/10.1111/bju.13116
M3 - Article
C2 - 25754526
SN - 1464-4096
VL - 117
SP - 598
EP - 603
JO - BJU international
JF - BJU international
IS - 4
ER -