T1 - How Do Laboratories Perform von Willebrand Disease Diagnostics and Classification of von Willebrand Disease Patients? Results from External Quality Data and an International Survey
AU - Hollestelle, Martine J.
AU - Meijers, Joost C. M.
AU - Meijer, Piet
N1 - Publisher Copyright: © 2022. Thieme. All rights reserved.
PY - 2022
Y1 - 2022
N2 - Background Reduced or dysfunctional von Willebrand factor (VWF) may lead to von Willebrand disease (VWD), which is a common inherited bleeding disorder. VWD is classified into three major types: type 1 is a partial quantitative deficiency of VWF, type 3 is a complete quantitative deficiency of VWF, and type 2 consists of qualitative abnormalities of VWF. To arrive at a correct VWD diagnosis, multiple tests and a correct interpretation of these tests are needed. Aim The aim of the present study was to gain insight into the approach of laboratories toward VWD diagnosis. Methods Data from four samples of the external quality assessment (EQA) VWF surveys of the ECAT (External Quality Control for Assays and Tests) were evaluated. Furthermore, results were analyzed of a questionnaire that was sent to hemostasis laboratories about VWD diagnostic approaches. Results For most EQA samples, the majority of participants indicated the correct classification. However, 6 to 60% indicated another classification. For all samples, significant differences in VWF results were observed between the correct and incorrect classifications. The questionnaire demonstrated that the testing approach varied between the laboratories, especially for parameters that were essential for discrimination between VWD type 1 and healthy individuals, as well as the cutoff values used to discriminate VWD types 1 and 2. Conclusions Diagnosis of VWD is heterogeneous in diagnostic approach, guidelines, and cutoff values within large ranges of VWF results between laboratories. Harmonization of approaches and increased accuracy of VWF measurements may help to establish a correct diagnosis.
AB - Background Reduced or dysfunctional von Willebrand factor (VWF) may lead to von Willebrand disease (VWD), which is a common inherited bleeding disorder. VWD is classified into three major types: type 1 is a partial quantitative deficiency of VWF, type 3 is a complete quantitative deficiency of VWF, and type 2 consists of qualitative abnormalities of VWF. To arrive at a correct VWD diagnosis, multiple tests and a correct interpretation of these tests are needed. Aim The aim of the present study was to gain insight into the approach of laboratories toward VWD diagnosis. Methods Data from four samples of the external quality assessment (EQA) VWF surveys of the ECAT (External Quality Control for Assays and Tests) were evaluated. Furthermore, results were analyzed of a questionnaire that was sent to hemostasis laboratories about VWD diagnostic approaches. Results For most EQA samples, the majority of participants indicated the correct classification. However, 6 to 60% indicated another classification. For all samples, significant differences in VWF results were observed between the correct and incorrect classifications. The questionnaire demonstrated that the testing approach varied between the laboratories, especially for parameters that were essential for discrimination between VWD type 1 and healthy individuals, as well as the cutoff values used to discriminate VWD types 1 and 2. Conclusions Diagnosis of VWD is heterogeneous in diagnostic approach, guidelines, and cutoff values within large ranges of VWF results between laboratories. Harmonization of approaches and increased accuracy of VWF measurements may help to establish a correct diagnosis.
KW - external quality assessment
KW - laboratory
KW - von Willebrand disease
UR - http://www.scopus.com/inward/record.url?scp=85138147098&partnerID=8YFLogxK
U2 - https://doi.org/10.1055/s-0042-1757137
DO - https://doi.org/10.1055/s-0042-1757137
M3 - Article
C2 - 36055267
SN - 0094-6176
JO - Seminars in Thrombosis and Hemostasis
JF - Seminars in Thrombosis and Hemostasis
ER -