TY - JOUR
T1 - In vivo interaction of endotoxin and recombinant bactericidal/permeability-increasing protein (rBPI23): hemodynamic effects in a human endotoxemia model
AU - Jellema, Wilbert T.
AU - Veerman, D. Peter
AU - de Winter, Robbert J.
AU - Wesseling, Karel H.
AU - van Deventer, Sander J. H.
AU - Hack, C. Erik
AU - van Lieshout, Johannes J.
PY - 2002
Y1 - 2002
N2 - The cardiovascular derangement that results from the administration of endotoxin in healthy subjects is qualitatively similar to what is observed in patients in septic shock. The biological response to endotoxin is attributed in part to cytokine release. In experimental endotoxemia, recombinant bactericidal/permeability increasing protein (rBPI(23)) has shown a protective effect by binding endotoxin with the subsequent inhibition of the endotoxin-induced cytokine release and of neutrophil activation. In a controlled, blinded crossover study the early cardiovascular effects of rBPI(23) were investigated in an experimental endotoxemia model in humans. The beat-to-beat changes in arterial pressure and cardiac output following infusion of endotoxin (40 EU/kg body weight) and rBPI(23) (1 mg/kg) or placebo (human serum albumin, 0.2 mg/kg) were studied for 2 hours in 8 healthy male adults. Endotoxin or rBPI(23) alone did not induce significant cardiovascular changes. Endotoxin following rBPI(23) infusion elicited a fall in total peripheral resistance with its nadir after 4 minutes to 40% (range 16-53; P <.001) of control level. Mean arterial pressure showed little change, and the fall in total peripheral resistance was associated with a reflex increase in heart rate and cardiac output (32%; range 43-106). Changes in cardiovascular variables in the subsequent 2 hours were not significant. In vitro activation of the contact system by, respectively, rBPI(23), LPS, and LPS-rBPI(23) complexes was assessed. Following incubation with rBPI(23), LPS, and LPS-rBPI(23) complexes, complex levels were generated at levels comparable to those observed in the buffer control. The rapid vasodilatation by endotoxin administered concomitantly with rBPI(23) is not mediated by complement or contact system activation. The early vasodilatation is compensated by an increase in cardiac output, which therefore does not result in arterial hypotension. The monitoring of continuous cardiac output allows for the detection of rapid effects on systemic flow and conductance that go unnoticed in a recording of arterial pressure
AB - The cardiovascular derangement that results from the administration of endotoxin in healthy subjects is qualitatively similar to what is observed in patients in septic shock. The biological response to endotoxin is attributed in part to cytokine release. In experimental endotoxemia, recombinant bactericidal/permeability increasing protein (rBPI(23)) has shown a protective effect by binding endotoxin with the subsequent inhibition of the endotoxin-induced cytokine release and of neutrophil activation. In a controlled, blinded crossover study the early cardiovascular effects of rBPI(23) were investigated in an experimental endotoxemia model in humans. The beat-to-beat changes in arterial pressure and cardiac output following infusion of endotoxin (40 EU/kg body weight) and rBPI(23) (1 mg/kg) or placebo (human serum albumin, 0.2 mg/kg) were studied for 2 hours in 8 healthy male adults. Endotoxin or rBPI(23) alone did not induce significant cardiovascular changes. Endotoxin following rBPI(23) infusion elicited a fall in total peripheral resistance with its nadir after 4 minutes to 40% (range 16-53; P <.001) of control level. Mean arterial pressure showed little change, and the fall in total peripheral resistance was associated with a reflex increase in heart rate and cardiac output (32%; range 43-106). Changes in cardiovascular variables in the subsequent 2 hours were not significant. In vitro activation of the contact system by, respectively, rBPI(23), LPS, and LPS-rBPI(23) complexes was assessed. Following incubation with rBPI(23), LPS, and LPS-rBPI(23) complexes, complex levels were generated at levels comparable to those observed in the buffer control. The rapid vasodilatation by endotoxin administered concomitantly with rBPI(23) is not mediated by complement or contact system activation. The early vasodilatation is compensated by an increase in cardiac output, which therefore does not result in arterial hypotension. The monitoring of continuous cardiac output allows for the detection of rapid effects on systemic flow and conductance that go unnoticed in a recording of arterial pressure
U2 - https://doi.org/10.1067/mlc.2002.127170
DO - https://doi.org/10.1067/mlc.2002.127170
M3 - Article
C2 - 12389020
SN - 0022-2143
VL - 140
SP - 228
EP - 235
JO - Journal of laboratory and clinical medicine
JF - Journal of laboratory and clinical medicine
IS - 4
ER -