T1 - Intraindividual quantitative and qualitative comparison of gadopentetate dimeglumine and gadobutrol in time-resolved contrast-enhanced 4-dimensional magnetic resonance angiography in minipigs
AU - Hadizadeh, Dariusch Reza
AU - Jost, Gregor
AU - Pietsch, Hubertus
AU - Weibrecht, Martin
AU - Perkuhn, Michael
AU - Boschewitz, Jack Maria
AU - Keil, Vera Catharina
AU - Träber, Frank
AU - Kukuk, Guido Matthias
AU - Schild, Hans Heinz
AU - Willinek, Winfried Albert
PY - 2014
Y1 - 2014
N2 - OBJECTIVES: The concentration and relaxivities of contrast agents affect quantitative and qualitative image quality in contrast-enhanced time-resolved 4-dimensional magnetic resonance angiography (4D-MRA). Gadobutrol has a high relaxivity and is the only gadolinium (Gd)-based contrast agent approved for clinical use at a 1 M concentration. This promises to confer superior bolus characteristics by generating a steeper and shorter bolus with a higher peak Gd concentration. The purpose of this study was to quantitatively examine bolus characteristics of 1 M gadobutrol compared with 0.5 M gadopentetate dimeglumine and to evaluate image quality in thoracoabdominal 4D-MRA. MATERIALS AND METHODS: A total of 7 Goettingen minipigs received dynamic computed tomography (CT) on a clinical 64-slice CT (transverse slices, 80 kV, 20 seconds, 0.3 s/dynamic frame) and 4D-MRA (time-resolved imaging with stochastic trajectories; 1. transverse slices, 30 seconds, 0.49 s/frame; 2. coronal slices, 70 seconds, 1.3 s/frame) on a 1.5-T clinical whole-body magnetic resonance imaging under general anesthesia using gadopentetate dimeglumine and gadobutrol in an intraindividual comparative study. Computed tomography attenuations were converted into Gd concentrations on the basis of previous phantom experiments. Quantitative analysis included measurements of the full width at half maximum, time-To-peak intervals, and peak of each bolus in dynamic CT and transverse 4D-MRA. These studies were carried out at equivalent contrast agent flow rates of 1 mL/s. Quantitative analysis (7 arteries and veins) and qualitative image analysis were performed on coronal thoracoabdominal 4D-MRA studies carried out at flow rates of 1 mL/s and, in the case of gadopentetate dimeglumine, also at molarity-Adjusted flow rates of 2 mL/s. RESULTS: The bolus in both transverse 4D-MRA and dynamic CT was significantly narrower (full width at half maximum), earlier (time to peak), and higher (signal intensity enhancement in 4D-MRA, Gd concentration in dynamic CT) when using gadobutrol instead of gadopentetate dimeglumine at a flow rate of 1.0 mL/s (P = 0.008-< 0.0001). In thoracoabdominal 4D-MRA, the signal intensity level and overall image quality were highest in examinations with gadobutrol, followed by examinations with gadopentetate dimeglumine at flow rates of 2 mL/s, and lowest in examinations with gadopentetate dimeglumine at flow rates of 1 mL/s. CONCLUSIONS: A more compact bolus shape was observed after administration of gadobutrol compared with gadopentetate dimeglumine in minipigs. This was demonstrated both in 4D-MRA, where Gd concentration, relaxivity, and the image-Acquisition technique play a role, and in CT, where the signal intensity depends only on the Gd concentration. The overall image quality was rated higher in examinations with 1.0 M gadobutrol than with 0.5 M gadopentetate dimeglumine. Copyright © 2014 by Lippincott Williams & Wilkins.
AB - OBJECTIVES: The concentration and relaxivities of contrast agents affect quantitative and qualitative image quality in contrast-enhanced time-resolved 4-dimensional magnetic resonance angiography (4D-MRA). Gadobutrol has a high relaxivity and is the only gadolinium (Gd)-based contrast agent approved for clinical use at a 1 M concentration. This promises to confer superior bolus characteristics by generating a steeper and shorter bolus with a higher peak Gd concentration. The purpose of this study was to quantitatively examine bolus characteristics of 1 M gadobutrol compared with 0.5 M gadopentetate dimeglumine and to evaluate image quality in thoracoabdominal 4D-MRA. MATERIALS AND METHODS: A total of 7 Goettingen minipigs received dynamic computed tomography (CT) on a clinical 64-slice CT (transverse slices, 80 kV, 20 seconds, 0.3 s/dynamic frame) and 4D-MRA (time-resolved imaging with stochastic trajectories; 1. transverse slices, 30 seconds, 0.49 s/frame; 2. coronal slices, 70 seconds, 1.3 s/frame) on a 1.5-T clinical whole-body magnetic resonance imaging under general anesthesia using gadopentetate dimeglumine and gadobutrol in an intraindividual comparative study. Computed tomography attenuations were converted into Gd concentrations on the basis of previous phantom experiments. Quantitative analysis included measurements of the full width at half maximum, time-To-peak intervals, and peak of each bolus in dynamic CT and transverse 4D-MRA. These studies were carried out at equivalent contrast agent flow rates of 1 mL/s. Quantitative analysis (7 arteries and veins) and qualitative image analysis were performed on coronal thoracoabdominal 4D-MRA studies carried out at flow rates of 1 mL/s and, in the case of gadopentetate dimeglumine, also at molarity-Adjusted flow rates of 2 mL/s. RESULTS: The bolus in both transverse 4D-MRA and dynamic CT was significantly narrower (full width at half maximum), earlier (time to peak), and higher (signal intensity enhancement in 4D-MRA, Gd concentration in dynamic CT) when using gadobutrol instead of gadopentetate dimeglumine at a flow rate of 1.0 mL/s (P = 0.008-< 0.0001). In thoracoabdominal 4D-MRA, the signal intensity level and overall image quality were highest in examinations with gadobutrol, followed by examinations with gadopentetate dimeglumine at flow rates of 2 mL/s, and lowest in examinations with gadopentetate dimeglumine at flow rates of 1 mL/s. CONCLUSIONS: A more compact bolus shape was observed after administration of gadobutrol compared with gadopentetate dimeglumine in minipigs. This was demonstrated both in 4D-MRA, where Gd concentration, relaxivity, and the image-Acquisition technique play a role, and in CT, where the signal intensity depends only on the Gd concentration. The overall image quality was rated higher in examinations with 1.0 M gadobutrol than with 0.5 M gadopentetate dimeglumine. Copyright © 2014 by Lippincott Williams & Wilkins.
KW - Animals
KW - Arteries/anatomy & histology
KW - Blood Flow Velocity/physiology
KW - Contrast Media
KW - Female
KW - Gadolinium DTPA
KW - Image Enhancement/methods
KW - Image Interpretation, Computer-Assisted/methods
KW - Magnetic Resonance Angiography/methods
KW - Organometallic Compounds
KW - Reproducibility of Results
KW - Sensitivity and Specificity
KW - Swine
KW - Swine, Miniature
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=84902206548&origin=inward
UR - https://www.ncbi.nlm.nih.gov/pubmed/24598442
U2 - https://doi.org/10.1097/RLI.0000000000000036
DO - https://doi.org/10.1097/RLI.0000000000000036
M3 - Article
C2 - 24598442
SN - 0020-9996
VL - 49
SP - 457
EP - 464
JO - Investigative radiology
JF - Investigative radiology
IS - 7
ER -