TY - JOUR
T1 - Low Transmission of Airway Pressures to the Abdomen in Mechanically Ventilated Patients with or Without Acute Respiratory Failure and Intra-Abdominal Hypertension
AU - Heijnen, Bram G.A.D.H.
AU - Spoelstra-De Man, Angelique M.E.
AU - Groeneveld, A. B.Johan
PY - 2017
Y1 - 2017
N2 - Purpose: Intra-abdominal pressure, measured at end expiration, may depend on ventilator settings and transmission of intrathoracic pressure. We determined the transmission of positive intrathoracic pressure during mechanical ventilation at inspiration and expiration into the abdominal compartment. Methods and Results: We included 9 patients after uncomplicated cardiac surgery and 9 with acute respiratory failure. Intravesical pressures were measured thrice (reproducibility of 1.8%) and averaged, at the end of each inspiratory and expiratory hold maneuvers of 5 seconds. Transmission, the change in intra-abdominal over intrathoracic pressures from end inspiration to end expiration, was about 8%. End-expiratory intra-abdominal pressure was lower than "total" intra-abdominal pressure over the entire respiratory cycle by 0.34 cm H2O. It was 0.73 cm H2O higher than "true" intra-abdominal pressure over the entire respiratory cycle, taking transmission into account. The percentage error was 3% for total and 10% for true pressure. Results did not differ among patients with or without acute respiratory failure and decreased respiratory compliance or between those with (≥12 mm Hg, n = 5) or without intra-abdominal hypertension. Conclusions: Transmitted airway pressure only slightly affects intra-abdominal pressure in mechanically ventilated patients, irrespective of respiratory compliance and baseline intra-abdominal pressure values. End-expiratory measurements referenced against atmospheric pressure may suffice for clinical practice.
AB - Purpose: Intra-abdominal pressure, measured at end expiration, may depend on ventilator settings and transmission of intrathoracic pressure. We determined the transmission of positive intrathoracic pressure during mechanical ventilation at inspiration and expiration into the abdominal compartment. Methods and Results: We included 9 patients after uncomplicated cardiac surgery and 9 with acute respiratory failure. Intravesical pressures were measured thrice (reproducibility of 1.8%) and averaged, at the end of each inspiratory and expiratory hold maneuvers of 5 seconds. Transmission, the change in intra-abdominal over intrathoracic pressures from end inspiration to end expiration, was about 8%. End-expiratory intra-abdominal pressure was lower than "total" intra-abdominal pressure over the entire respiratory cycle by 0.34 cm H2O. It was 0.73 cm H2O higher than "true" intra-abdominal pressure over the entire respiratory cycle, taking transmission into account. The percentage error was 3% for total and 10% for true pressure. Results did not differ among patients with or without acute respiratory failure and decreased respiratory compliance or between those with (≥12 mm Hg, n = 5) or without intra-abdominal hypertension. Conclusions: Transmitted airway pressure only slightly affects intra-abdominal pressure in mechanically ventilated patients, irrespective of respiratory compliance and baseline intra-abdominal pressure values. End-expiratory measurements referenced against atmospheric pressure may suffice for clinical practice.
KW - abdominal compliance
KW - acute respiratory distress syndrome
KW - acute respiratory failure
KW - intra-abdominal hypertension
KW - positive end-expiratory pressures
KW - respiratory compliance
UR - http://www.scopus.com/inward/record.url?scp=85011685063&partnerID=8YFLogxK
U2 - https://doi.org/10.1177/0885066615625180
DO - https://doi.org/10.1177/0885066615625180
M3 - Article
C2 - 26732769
SN - 0885-0666
VL - 32
SP - 218
EP - 222
JO - Journal of intensive care medicine
JF - Journal of intensive care medicine
IS - 3
ER -