TY - JOUR
T1 - Reproducibility of APT-weighted CEST-MRI at 3T in healthy brain and tumor across sessions and scanners
AU - Wu, Yulun
AU - Wood, Tobias C.
AU - Derks, Sophie H. A. E.
AU - Pruis, Ilanah J.
AU - van der Voort, Sebastian
AU - van Zanten, Sophie E. M. Veldhuijzen
AU - Smits, Marion
AU - Warnert, Esther A. H.
N1 - Funding Information: This research was conducted with support from the Brain Tumour Charity: “Making the invisible visible: In vivo mapping of molecular biomarkers in adult diffuse glioma with CEST MRI”, GN-000540. E.W. is funded by a “Veni Vernieuwingsimpuls” from the Dutch Research Council entitled “Food for thought: Oxygen delivery to the brain”, grant number 91619121. The Passage Study is financially supported by the Semmy Foundation (Stichting Semmy). Publisher Copyright: © 2023, Springer Nature Limited.
PY - 2023/12/1
Y1 - 2023/12/1
N2 - Amide proton transfer (APT)-weighted chemical exchange saturation transfer (CEST) imaging is a recent MRI technique making its way into clinical application. In this work, we investigated whether APT-weighted CEST imaging can provide reproducible measurements across scan sessions and scanners. Within-session, between-session and between scanner reproducibility was calculated for 19 healthy volunteers and 7 patients with a brain tumor on two 3T MRI scanners. The APT-weighted CEST effect was evaluated by calculating the Lorentzian Difference (LD), magnetization transfer ratio asymmetry (MTRasym), and relaxation-compensated inverse magnetization transfer ratio (MTRREX) averaged in whole brain white matter (WM), enhancing tumor and necrosis. Within subject coefficient of variation (COV) calculations, Bland–Altman plots and mixed effect modeling were performed to assess the repeatability and reproducibility of averaged values. The group median COVs of LD APT were 0.56% (N = 19), 0.84% (N = 6), 0.80% (N = 9) in WM within-session, between-session and between-scanner respectively. The between-session COV of LD APT in enhancing tumor (N = 6) and necrotic core (N = 3) were 4.57% and 5.67%, respectively. There were no significant differences in within session, between session and between scanner comparisons of the APT effect. The COVs of LD and MTRREX were consistently lower than MTRasym in all experiments, both in healthy tissues and tumor. The repeatability and reproducibility of APT-weighted CEST was clinically acceptable across scan sessions and scanners. Although MTRasym is simple to acquire and compute and sufficient to provide robust measurement, it is beneficial to include LD and MTRREX to obtain higher reproducibility for detecting minor signal difference in different tissue types.
AB - Amide proton transfer (APT)-weighted chemical exchange saturation transfer (CEST) imaging is a recent MRI technique making its way into clinical application. In this work, we investigated whether APT-weighted CEST imaging can provide reproducible measurements across scan sessions and scanners. Within-session, between-session and between scanner reproducibility was calculated for 19 healthy volunteers and 7 patients with a brain tumor on two 3T MRI scanners. The APT-weighted CEST effect was evaluated by calculating the Lorentzian Difference (LD), magnetization transfer ratio asymmetry (MTRasym), and relaxation-compensated inverse magnetization transfer ratio (MTRREX) averaged in whole brain white matter (WM), enhancing tumor and necrosis. Within subject coefficient of variation (COV) calculations, Bland–Altman plots and mixed effect modeling were performed to assess the repeatability and reproducibility of averaged values. The group median COVs of LD APT were 0.56% (N = 19), 0.84% (N = 6), 0.80% (N = 9) in WM within-session, between-session and between-scanner respectively. The between-session COV of LD APT in enhancing tumor (N = 6) and necrotic core (N = 3) were 4.57% and 5.67%, respectively. There were no significant differences in within session, between session and between scanner comparisons of the APT effect. The COVs of LD and MTRREX were consistently lower than MTRasym in all experiments, both in healthy tissues and tumor. The repeatability and reproducibility of APT-weighted CEST was clinically acceptable across scan sessions and scanners. Although MTRasym is simple to acquire and compute and sufficient to provide robust measurement, it is beneficial to include LD and MTRREX to obtain higher reproducibility for detecting minor signal difference in different tissue types.
UR - http://www.scopus.com/inward/record.url?scp=85174826460&partnerID=8YFLogxK
U2 - https://doi.org/10.1038/s41598-023-44891-0
DO - https://doi.org/10.1038/s41598-023-44891-0
M3 - Article
C2 - 37872418
SN - 2045-2322
VL - 13
JO - Scientific reports
JF - Scientific reports
IS - 1
M1 - 18115
ER -