Saphenous vein graft failure and clinical outcomes: toward a surrogate end point in patients following coronary artery bypass surgery?

Ralf E. Harskamp, Judson B. Williams, Ronald C. Hill, Robbert J. de Winter, John H. Alexander, Renato D. Lopes

Research output: Contribution to journalEditorialAcademicpeer-review

43 Citations (Scopus)

Abstract

Saphenous vein graft (SVG) failure is a common finding in patients following coronary artery bypass graft (CABG) surgery. In the literature SVG failure rates have been reported from 25 to over 50% within 10 years. Although common, it remains unclear to what extent SVG failure affects clinical outcome, due to differences in definition, patient selection and follow-up. Particularly the lack of agreement on a universal definition makes comparisons between studies, and therefore generalizability of associations with outcomes, challenging. We suggest using a definition of SVG failure that is based on imaging as well as clinical parameters, that includes reporting SVG failure on both graft and patient level. The use of non-invasive imaging may help improve follow-up rates, and provide a more accurate picture of the real incidence and clinical impact of SVG failure. Given the lack of supportive evidence showing a consistent association between SVG failure and major adverse cardiovascular events, SVG failure should not be considered a valid surrogate endpoint at this time
Original languageEnglish
Pages (from-to)639-643
JournalAmerican Heart Journal
Volume165
Issue number5
DOIs
Publication statusPublished - 2013

Cite this