T1 - Semiautomatic sizing software in emergency endovascular aneurysm repair for ruptured abdominal aortic aneurysms
AU - Reimerink, Jorik J.
AU - Marquering, Henk A.
AU - Vahl, Anco
AU - Wisselink, Willem
AU - Schreve, Michiel A.
AU - de Boo, Diederick W.
AU - Reekers, Jim A.
AU - Legemate, Dink A.
AU - Balm, Ron
PY - 2014
Y1 - 2014
N2 - In emergency endovascular repair (EVAR) of ruptured aneurysms of the aorta (rAAA), anatomical suitability must be determined. Semiautomatic three-dimensional assessment of the aortoiliac arteries has the potential to standardise measurements. This study assesses the fitness for purpose of such a semiautomatic approach for rAAA and determined interobserver agreement on suitability. Interobserver study with six trained observers (4 vascular surgeons, 2 radiologists) blindly assessing preoperative computed tomography angiography scans of 50 consecutive patients with rAAA. A central lumen line (CLL) was generated, and perpendicular diameters, length along the CLL, and EVAR suitability were determined using dedicated sizing software (3mensio; 3mensio Vascular; Bilthoven, The Netherlands). Success of generating a CLL, time of assessment, and interobserver agreement was determined. In the majority of the patients (median 76 %, range 64-78 %), a CLL was semiautomatically generated. The median duration of CLL generation and performance measurements was 7.5 min (interquartile range 5.5-10.6). Agreement on suitability was moderate for the entire group (Fleiss' κ = 0.55, confidence interval 0.48-0.62) and ranged from moderate to good (Cohen's κ = 0.40-0.72) between observer pairs. Assessing EVAR suitability of rAAA patients using dedicated sizing software is possible in the majority of patients. The measurements can be performed in a reasonable amount of time, and the agreement of suitability for EVAR in patients with rAAA is moderate. Improvements and additional research are necessary to replace the current axial measurement
AB - In emergency endovascular repair (EVAR) of ruptured aneurysms of the aorta (rAAA), anatomical suitability must be determined. Semiautomatic three-dimensional assessment of the aortoiliac arteries has the potential to standardise measurements. This study assesses the fitness for purpose of such a semiautomatic approach for rAAA and determined interobserver agreement on suitability. Interobserver study with six trained observers (4 vascular surgeons, 2 radiologists) blindly assessing preoperative computed tomography angiography scans of 50 consecutive patients with rAAA. A central lumen line (CLL) was generated, and perpendicular diameters, length along the CLL, and EVAR suitability were determined using dedicated sizing software (3mensio; 3mensio Vascular; Bilthoven, The Netherlands). Success of generating a CLL, time of assessment, and interobserver agreement was determined. In the majority of the patients (median 76 %, range 64-78 %), a CLL was semiautomatically generated. The median duration of CLL generation and performance measurements was 7.5 min (interquartile range 5.5-10.6). Agreement on suitability was moderate for the entire group (Fleiss' κ = 0.55, confidence interval 0.48-0.62) and ranged from moderate to good (Cohen's κ = 0.40-0.72) between observer pairs. Assessing EVAR suitability of rAAA patients using dedicated sizing software is possible in the majority of patients. The measurements can be performed in a reasonable amount of time, and the agreement of suitability for EVAR in patients with rAAA is moderate. Improvements and additional research are necessary to replace the current axial measurement
U2 - https://doi.org/10.1007/s00270-013-0757-1
DO - https://doi.org/10.1007/s00270-013-0757-1
M3 - Article
C2 - 24174211
SN - 0174-1551
VL - 37
SP - 623
EP - 630
JO - Cardiovascular and interventional radiology
JF - Cardiovascular and interventional radiology
IS - 3
ER -