Some Patients Are More Equal Than Others: Variation in Ventilator Settings for Coronavirus Disease 2019 Acute Respiratory Distress Syndrome

Tariq A Dam, Harm-Jan de Grooth, Thomas Klausch, Lucas M Fleuren, Daan P de Bruin, Robert Entjes, Thijs C D Rettig, Dave A Dongelmans, Age D Boelens, Sander Rigter, Stefaan H A Hendriks, Remko de Jong, Marlijn J A Kamps, Marco Peters, A Karakus, Diederik Gommers, Dharmanand Ramnarain, Evert-Jan Wils, Sefanja Achterberg, Ralph NowitzkyWalter van den Tempel, Cornelis P C de Jager, Fleur G C A Nooteboom, Evelien Oostdijk, Peter Koetsier, Alexander D Cornet, Auke C Reidinga, Wouter de Ruijter, Rob J Bosman, Tim Frenzel, Louise C Urlings-Strop, Paul de Jong, Ellen G M Smit, Olaf L Cremer, D Jannet Mehagnoul-Schipper, Harald J Faber, Judith Lens, Gert B Brunnekreef, Barbara Festen-Spanjer, Tom Dormans, Annemieke Dijkstra, Bram Simons, A A Rijkeboer, Sesmu Arbous, Marcel Aries, Menno Beukema, Daniël Pretorius, Rutger van Raalte, Martijn van Tellingen, Niels C Gritters van den Oever, Robbert C A Lalisang, Michele Tonutti, Armand R J Girbes, Mark Hoogendoorn, Patrick J Thoral, Paul W G Elbers

Research output: Contribution to journalArticleAcademicpeer-review

Abstract

OBJECTIVES: As coronavirus disease 2019 is a novel disease, treatment strategies continue to be debated. This provides the intensive care community with a unique opportunity as the population of coronavirus disease 2019 patients requiring invasive mechanical ventilation is relatively homogeneous compared with other ICU populations. We hypothesize that the novelty of coronavirus disease 2019 and the uncertainty over its similarity with noncoronavirus disease 2019 acute respiratory distress syndrome resulted in substantial practice variation between hospitals during the first and second waves of coronavirus disease 2019 patients.

DESIGN: Multicenter retrospective cohort study.

SETTING: Twenty-five hospitals in the Netherlands from February 2020 to July 2020, and 14 hospitals from August 2020 to December 2020.

PATIENTS: One thousand two hundred ninety-four critically ill intubated adult ICU patients with coronavirus disease 2019 were selected from the Dutch Data Warehouse. Patients intubated for less than 24 hours, transferred patients, and patients still admitted at the time of data extraction were excluded.

MEASUREMENTS AND MAIN RESULTS: We aimed to estimate between-ICU practice variation in selected ventilation parameters (positive end-expiratory pressure, Fio2, set respiratory rate, tidal volume, minute volume, and percentage of time spent in a prone position) on days 1, 2, 3, and 7 of intubation, adjusted for patient characteristics as well as severity of illness based on Pao2/Fio2 ratio, pH, ventilatory ratio, and dynamic respiratory system compliance during controlled ventilation. Using multilevel linear mixed-effects modeling, we found significant (p ≤ 0.001) variation between ICUs in all ventilation parameters on days 1, 2, 3, and 7 of intubation for both waves.

CONCLUSIONS: This is the first study to clearly demonstrate significant practice variation between ICUs related to mechanical ventilation parameters that are under direct control by intensivists. Their effect on clinical outcomes for both coronavirus disease 2019 and other critically ill mechanically ventilated patients could have widespread implications for the practice of intensive care medicine and should be investigated further by causal inference models and clinical trials.

Original languageEnglish
Pages (from-to)e0555
JournalCritical Care Explorations
Volume3
Issue number10
DOIs
Publication statusPublished - Oct 2021

Cite this