Temporal Evolution of Serum Concentrations of High-Sensitivity Cardiac Troponin During 1 Year After Acute Coronary Syndrome Admission

BIOMArCS investigators *

Research output: Contribution to journalArticleAcademicpeer-review

5 Citations (Scopus)

Abstract

Background Detailed insights in temporal evolution of high-sensitivity cardiac troponin following acute coronary syndrome (ACS) are currently missing. We aimed to describe and compare the post-ACS kinetics of high-sensitivity cardiac troponin I (hs-cTnI) and high-sensitivity cardiac troponin T (hs-cTnT), and to determine their intra- and interindividual variation in clinically stable patients. Methods and Results We determined hs-cTnI (Abbott) and hs-cTnT (Roche) in 1507 repeated blood samples, derived from 191 patients with ACS (median, 8/patient) who remained free from adverse cardiac events during 1-year follow-up. Post-ACS kinetics were studied by linear mixed-effect models. Using the samples collected in the 6- to 12-month post-ACS time frame, patients were then considered to have chronic coronary syndrome. We determined (differences between) the average hs-cTnI and average hs-cTnT concentration, and the intra- and interindividual variation for both biomarkers. Compared with hs-cTnT, hs-cTnI peaked higher (median 3506 ng/L versus 494 ng/L; P<0.001) and was quicker below the biomarker-specific upper reference limit (16 versus 19 days; P<0.001). In the post-6-month samples, hs-cTnI and hs-cTnT showed modest correlation (rspearman=0.60), whereas the average hs-cTnT concentration was 5 times more likely to be above the upper reference limit than hs-cTnI. The intraindividual variations of hs-cTnI and hs-cTnT were 14.0% and 18.1%, while the interindividual variations were 94.1% and 75.9%. Conclusions Hs-cTnI peaked higher after ACS and was quicker below the upper reference limit. In the post-6-month samples, hs-cTnI and hs-cTnT were clearly not interchangeable, and average hs-cTnT concentrations were much more often above the upper reference limit than hs-cTnI. For both markers, the within-patient variation fell largely below beween-patient variation. Registration URL: https://www.trialregister.nl; unique identifiers: NTR1698 and NTR1106.
Original languageEnglish
Article numbere017393
Pages (from-to)1-13
Number of pages13
JournalJournal of the American Heart Association
Volume10
Issue number1
DOIs
Publication statusPublished - 5 Jan 2021

Keywords

  • Biological variation
  • longitudinal studies
  • myocardial infarction
  • precision medicine
  • troponinm

Cite this