T1 - The value of radio frequency identification in quality management of the blood transfusion chain in an academic hospital setting
AU - Dusseljee-Peute, Linda W.
AU - Van der Togt, Remko
AU - Jansen, Bas
AU - Jaspers, Monique W.
N1 - Funding Information: This study was performed within the AMC, a large academic hospital in Amsterdam, the Netherlands. The AMC is a 1002 beds hospital including 21 outpatient clinics, 34 inpatient clinics, 5 day care units, employing 960 full-time equivalent clinicians in total. The study was part of the project “RFID in health care.” This project was initiated and sponsored by the Dutch Ministry of Health, Welfare and Sport. This study was part of this project and gathered data at the blood transfusion laboratory (BTL), the operating room complex, and the intensive care unit (ICU) of the AMC. Funding Information: This research was funded by the Dutch Ministry of Health, Welfare and Sport; the Ministry of Economic Affairs; the Academic Medical Center; Capgemini; Geodan; Oracle; and Intel. They had no influence on the content of this manuscript. Publisher Copyright: © 2019 JMIR Publications Inc.. All right reserved.
PY - 2019
Y1 - 2019
N2 - Background: A complex process like the blood transfusion chain could benefit from modern technologies such as radio frequency identification (RFID). RFID could, for example, play an important role in generating logistic and temperature data of blood products, which are important in assessing the quality of the logistic process of blood transfusions and the product itself. Objective: This study aimed to evaluate whether location, time stamp, and temperature data generated in real time by an active RFID system containing temperature sensors attached to red blood cell (RBC) products can be used to assess the compliance of the management of RBCs to 4 intrahospital European and Dutch guidelines prescribing logistic and temperature constraints in an academic hospital setting. Methods: An RFID infrastructure supported the tracking and tracing of 243 tagged RBCs in a clinical setting inside the hospital at the blood transfusion laboratory, the operating room complex, and the intensive care unit within the Academic Medical Center, a large academic hospital in Amsterdam, the Netherlands. The compliance of the management of 182 out of the 243 tagged RBCs could be assessed on their adherence to the following guidelines on intrahospital storage, transport, and distribution: (1) RBCs must be preserved within an environment with a temperature between 2°C and 6°C; (2) RBCs have to be transfused within 1 hour after they have left a validated cooling system; (3) RBCs that have reached a temperature above 10°C must not be restored or must be transfused within 24 hours or else be destroyed; (4) unused RBCs are to be returned to the BTL within 24 hours after they left the transfusion laboratory. Results: In total, 4 blood products (4/182 compliant; 2.2%) complied to all applicable guidelines. Moreover, 15 blood products (15/182 not compliant to 1 out of several guidelines; 8.2%) were not compliant to one of the guidelines of either 2 or 3 relevant guidelines. Finally, 148 blood products (148/182 not compliant to 2 guidelines; 81.3%) were not compliant to 2 out of the 3 relevant guidelines. Conclusions: The results point out the possibilities of using RFID technology to assess the quality of the blood transfusion chain itself inside a hospital setting in reference to intrahospital guidelines concerning the storage, transport, and distribution conditions of RBCs. This study shows the potentials of RFID in identifying potential bottlenecks in hospital organizations' processes by use of objective data, which are to be tackled in process redesign efforts. The effect of these efforts can subsequently be evaluated by the use of RFID again. As such, RFID can play a significant role in optimization of the quality of the blood transfusion chain.
AB - Background: A complex process like the blood transfusion chain could benefit from modern technologies such as radio frequency identification (RFID). RFID could, for example, play an important role in generating logistic and temperature data of blood products, which are important in assessing the quality of the logistic process of blood transfusions and the product itself. Objective: This study aimed to evaluate whether location, time stamp, and temperature data generated in real time by an active RFID system containing temperature sensors attached to red blood cell (RBC) products can be used to assess the compliance of the management of RBCs to 4 intrahospital European and Dutch guidelines prescribing logistic and temperature constraints in an academic hospital setting. Methods: An RFID infrastructure supported the tracking and tracing of 243 tagged RBCs in a clinical setting inside the hospital at the blood transfusion laboratory, the operating room complex, and the intensive care unit within the Academic Medical Center, a large academic hospital in Amsterdam, the Netherlands. The compliance of the management of 182 out of the 243 tagged RBCs could be assessed on their adherence to the following guidelines on intrahospital storage, transport, and distribution: (1) RBCs must be preserved within an environment with a temperature between 2°C and 6°C; (2) RBCs have to be transfused within 1 hour after they have left a validated cooling system; (3) RBCs that have reached a temperature above 10°C must not be restored or must be transfused within 24 hours or else be destroyed; (4) unused RBCs are to be returned to the BTL within 24 hours after they left the transfusion laboratory. Results: In total, 4 blood products (4/182 compliant; 2.2%) complied to all applicable guidelines. Moreover, 15 blood products (15/182 not compliant to 1 out of several guidelines; 8.2%) were not compliant to one of the guidelines of either 2 or 3 relevant guidelines. Finally, 148 blood products (148/182 not compliant to 2 guidelines; 81.3%) were not compliant to 2 out of the 3 relevant guidelines. Conclusions: The results point out the possibilities of using RFID technology to assess the quality of the blood transfusion chain itself inside a hospital setting in reference to intrahospital guidelines concerning the storage, transport, and distribution conditions of RBCs. This study shows the potentials of RFID in identifying potential bottlenecks in hospital organizations' processes by use of objective data, which are to be tackled in process redesign efforts. The effect of these efforts can subsequently be evaluated by the use of RFID again. As such, RFID can play a significant role in optimization of the quality of the blood transfusion chain.
KW - Automatic data processing
KW - Blood transfusion
KW - Geographic information systems
KW - Guideline adherence
KW - Radio waves
KW - Technology
KW - Temperature
UR - http://www.scopus.com/inward/record.url?scp=85097373272&partnerID=8YFLogxK
U2 - https://doi.org/10.2196/9510
DO - https://doi.org/10.2196/9510
M3 - Article
SN - 2291-9694
VL - 7
JO - JMIR medical informatics
JF - JMIR medical informatics
IS - 3
M1 - e9510