Applying the National Institute for Clinical Excellence criteria to patients treated with the Genous (TM) Bio-engineered R stent (TM): a sub-study of the e-HEALING (Healthy Endothelial Accelerated Lining Inhibits Neointimal Growth) worldwide registry

Margo Klomp, Peter Damman, Marcel A. M. Beijk, Sigmund Silber, Manfred Grisold, Expedito E. Ribeiro, Harry Suryapranata, Jaroslaw Wòjcik, Kui Hian Sim, Jan G. P. Tijssen, Robbert J. de Winter

Research output: Contribution to journalArticleAcademicpeer-review

8 Citations (Scopus)

Abstract

The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter a parts per thousand yen3 mm and lesion length a parts per thousand currency sign15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter <3.0 mm or lesion length > 15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with a parts per thousand yen1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group
Original languageEnglish
Pages (from-to)360-369
JournalHeart and vessels
Volume27
Issue number4
DOIs
Publication statusPublished - 2012

Cite this