Are adenoma and serrated polyp detection rates correlated with endoscopists' sensitivity of optical diagnosis?

DISCOUNT-2 study group

Research output: Contribution to journalArticleAcademicpeer-review

5 Citations (Scopus)

Abstract

UNLABELLED: INTRODUCTION : Endoscopists with a high adenoma detection rate (ADR) and proximal serrated polyp detection rate (PSPDR) detect these polyps more frequently, which may be attributable to better recognition of their endoscopic features. Little is known about the association between endoscopic lesion detection and differentiation skills. Therefore, we evaluated the correlation between the ADR, PSPDR, and the sensitivity of optical diagnosis for adenomas and serrated polyps.

METHODS: We performed an exploratory post-hoc analysis of the DISCOUNT-2 study, including complete colonoscopies after a positive fecal immunochemical test (FIT) performed by endoscopists who performed ≥ 50 colonoscopies. The correlations between the ADR, PSPDR, and the sensitivity of optical diagnosis were calculated using Pearson's rho correlation coefficient.

RESULTS: 24 endoscopists performed ≥ 50 colonoscopies, resulting in a total of 2889 colonoscopies. The overall ADR was 84.5 % (range 71.4 % - 95.3 %) and overall PSPDR was 13.7 % (4.3 % - 29.0 %). The sensitivity of optical diagnosis for adenomas and serrated polyps were 94.5 % (83.3 % - 100 %) and 74.0 % (37.5 % - 94.1 %), respectively. No correlation could be demonstrated between the ADR and the sensitivity of optical diagnosis for adenomas (-0.20; P = 0.35) or between the PSPDR and the sensitivity of optical diagnosis for serrated polyps (-0.12; P = 0.57).

CONCLUSIONS: In a homogeneous FIT-positive population, no correlation between the ADR, PSPDR, and the sensitivity of optical diagnosis for adenomas and serrated polyps could be demonstrated. These exploratory results suggest that lesion detection and differentiation require different endoscopic skills. Further prospective studies are needed; until then, monitoring of both performance indicators is important to secure optimal efficacy of FIT-based colorectal cancer screening.

Original languageEnglish
Pages (from-to)763-772
Number of pages10
JournalEndoscopy
Volume52
Issue number9
DOIs
Publication statusPublished - 1 Sept 2020

Keywords

  • Adenoma/diagnostic imaging
  • Colonic Polyps/diagnostic imaging
  • Colonoscopy
  • Colorectal Neoplasms/diagnostic imaging
  • Early Detection of Cancer
  • Humans
  • Prospective Studies

Cite this