Contrast-enhanced magnetic resonance angiography findings prior to hemodialysis vascular access creation: a prospective analysis

R. N. Planken, T. Leiner, R. J. Nijenhuis, L. E. Duijm, P. W. Cuypers, P. Douwes-Draaijer, F. M. van der Sande, A. G. Kessels, J. H. M. Tordoir

Research output: Contribution to journalArticleAcademicpeer-review

12 Citations (Scopus)

Abstract

To determine prospectively the clinical value of contrast-enhanced magnetic resonance angiography (CE-MRA) for assessment of the arterial inflow and venous outflow prior to vascular access (VA) creation. Seventy-three patients underwent duplex ultrasonography (DUS) and CE-MRA prior to VA creation for detection of stenoses and occlusions. Two observers read the CE-MRA images for determination of inter-observer agreement. A VA was considered functional if it could be used for successful two-needle hemodialysis therapy within 2 months after creation. CE-MRA detected 6 stenosed, 8 occluded arterial vessel segments and 12 stenosed and 41 occluded venous vessel segments in 70 patients. Inter-observer agreement for detection of upper extremity arterial and venous stenoses and occlusions with CE-MRA was substantial to almost perfect (kappa values 0.76-0.96). CE-MRA detected lesions, not detected by DUS, that were associated with VA early failure and non-maturation in 33% of patients (7/21). Accessory veins detected preoperatively were the cause of VA non-maturation in a substantial group of patients (47%: 7/15). CE-MRA enables accurate detection of upper extremity arterial and venous stenosis and occlusions prior to VA creation. Preoperative CE-MRA identified arterial and venous stenoses, not detected by DUS that were associated with VA early failure and non-maturation. However, the use of gadolinium containing contrast media is currently contraindicated due the reported incidence of nephrogenic systemic fibrosis
Original languageEnglish
Pages (from-to)269-277
JournalJournal of Vascular Access
Volume9
Issue number4
Publication statusPublished - 2008

Cite this