TY - JOUR
T1 - Design and evaluation of an MRI-ready, self-propelled needle for prostate interventions
AU - Bloemberg, Jette
AU - Trauzettel, Fabian
AU - Coolen, Bram
AU - Dodou, Dimitra
AU - Breedveld, Paul
N1 - Funding Information: This work was supported by the Netherlands Organisation for Scientific Research (Nederlandse Organisatie voor Wetenschappelijk Onderzoek, NWO), domain Applied and Engineering Sciences (TTW), and which is partly funded by the Ministry of Economic Affairs. Grant number 80450, Perspectief programme, Photonics Translational Research - Medical Photonics (MEDPHOT), awarded to PB. URL: https://www.nwo.nl/. Fabian Trauzettel is part of the ATLAS project. This project has received funding from the European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie, grant number 813782. URL: https://atlas-itn.eu. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript. Publisher Copyright: Copyright: © 2022 Bloemberg et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2022/9/1
Y1 - 2022/9/1
N2 - Prostate cancer diagnosis and focal laser ablation treatment both require the insertion of a needle for biopsy and optical fibre positioning. Needle insertion in soft tissues may cause tissue motion and deformation, which can, in turn, result in tissue damage and needle positioning errors. In this study, we present a prototype system making use of a wasp-inspired (bioinspired) self-propelled needle, which is able to move forward with zero external push force, thereby avoiding large tissue motion and deformation. Additionally, the actuation system solely consists of 3D printed parts and is therefore safe to use inside a magnetic resonance imaging (MRI) system. The needle consists of six parallel 0.25-mm diameter Nitinol rods driven by the actuation system. In the prototype, the self-propelled motion is achieved by advancing one needle segment while retracting the others. The advancing needle segment has to overcome a cutting and friction force while the retracting needle segments experience a friction force in the opposite direction. The needle self-propels through the tissue when the friction force of the five retracting needle segments overcomes the sum of the friction and cutting forces of the advancing needle segment. We tested the performance of the prototype in ex vivo human prostate tissue inside a preclinical MRI system in terms of the slip ratio of the needle with respect to the prostate tissue. The results showed that the needle was visible in MR images and that the needle was able to self-propel through the tissue with a slip ratio in the range of 0.78-0.95. The prototype is a step toward self-propelled needles for MRI-guided transperineal laser ablation as a method to treat prostate cancer.
AB - Prostate cancer diagnosis and focal laser ablation treatment both require the insertion of a needle for biopsy and optical fibre positioning. Needle insertion in soft tissues may cause tissue motion and deformation, which can, in turn, result in tissue damage and needle positioning errors. In this study, we present a prototype system making use of a wasp-inspired (bioinspired) self-propelled needle, which is able to move forward with zero external push force, thereby avoiding large tissue motion and deformation. Additionally, the actuation system solely consists of 3D printed parts and is therefore safe to use inside a magnetic resonance imaging (MRI) system. The needle consists of six parallel 0.25-mm diameter Nitinol rods driven by the actuation system. In the prototype, the self-propelled motion is achieved by advancing one needle segment while retracting the others. The advancing needle segment has to overcome a cutting and friction force while the retracting needle segments experience a friction force in the opposite direction. The needle self-propels through the tissue when the friction force of the five retracting needle segments overcomes the sum of the friction and cutting forces of the advancing needle segment. We tested the performance of the prototype in ex vivo human prostate tissue inside a preclinical MRI system in terms of the slip ratio of the needle with respect to the prostate tissue. The results showed that the needle was visible in MR images and that the needle was able to self-propel through the tissue with a slip ratio in the range of 0.78-0.95. The prototype is a step toward self-propelled needles for MRI-guided transperineal laser ablation as a method to treat prostate cancer.
UR - http://www.scopus.com/inward/record.url?scp=85137713071&partnerID=8YFLogxK
U2 - https://doi.org/10.1371/journal.pone.0274063
DO - https://doi.org/10.1371/journal.pone.0274063
M3 - Article
C2 - 36070302
SN - 1932-6203
VL - 17
JO - PLOS ONE
JF - PLOS ONE
IS - 9 September
M1 - e0274063
ER -