TY - JOUR
T1 - Different ventilation intensities among various categories of patients ventilated for reasons other than ARDS––A pooled analysis of 4 observational studies
AU - Serafini, Simon Corrado
AU - van Meenen, David M. P.
AU - Pisani, Luigi
AU - Neto, Ary Serpa
AU - Ball, Lorenzo
AU - de Abreu, Marcelo Gama
AU - Algera, Anna Geke
AU - Azevedo, Luciano
AU - ERICC
AU - Bellani, Giacomo
AU - LUNG SAFE
AU - Dondorp, Arjen M.
AU - PRoVENT
AU - Fan, Eddy
AU - PRoVENT-iMiC-investigators
AU - Laffey, John G.
AU - Pham, Tai
AU - Tschernko, Edda M.
AU - Schultz, Marcus J.
AU - van der Woude, Margaretha C. E.
N1 - Publisher Copyright: © 2024 The Authors
PY - 2024/6/1
Y1 - 2024/6/1
N2 - Purpose: We investigated driving pressure (ΔP) and mechanical power (MP) and associations with clinical outcomes in critically ill patients ventilated for reasons other than ARDS. Materials and methods: Individual patient data analysis of a pooled database that included patients from four observational studies of ventilation. ΔP and MP were compared among invasively ventilated non–ARDS patients with sepsis, with pneumonia, and not having sepsis or pneumonia. The primary endpoint was ΔP; secondary endpoints included MP, ICU mortality and length of stay, and duration of ventilation. Results: This analysis included 372 (11%) sepsis patients, 944 (28%) pneumonia patients, and 2040 (61%) patients ventilated for any other reason. On day 1, median ΔP was higher in sepsis (14 [11-18] cmH2O) and pneumonia patients (14 [11-18]cmH2O), as compared to patients not having sepsis or pneumonia (13 [10-16] cmH2O) (P < 0.001). Median MP was also higher in sepsis and pneumonia patients. ΔP, as opposed to MP, was associated with ICU mortality in sepsis and pneumonia patients. Conclusions: The intensity of ventilation differed between patients with sepsis or pneumonia and patients receiving ventilation for any other reason; ΔP was associated with higher mortality in sepsis and pneumonia patients. Registration: This post hoc analysis was not registered; the individual studies that were merged into the used database were registered at clinicaltrials.gov: NCT01268410 (ERICC), NCT02010073 (LUNG SAFE), NCT01868321 (PRoVENT), and NCT03188770 (PRoVENT–iMiC).
AB - Purpose: We investigated driving pressure (ΔP) and mechanical power (MP) and associations with clinical outcomes in critically ill patients ventilated for reasons other than ARDS. Materials and methods: Individual patient data analysis of a pooled database that included patients from four observational studies of ventilation. ΔP and MP were compared among invasively ventilated non–ARDS patients with sepsis, with pneumonia, and not having sepsis or pneumonia. The primary endpoint was ΔP; secondary endpoints included MP, ICU mortality and length of stay, and duration of ventilation. Results: This analysis included 372 (11%) sepsis patients, 944 (28%) pneumonia patients, and 2040 (61%) patients ventilated for any other reason. On day 1, median ΔP was higher in sepsis (14 [11-18] cmH2O) and pneumonia patients (14 [11-18]cmH2O), as compared to patients not having sepsis or pneumonia (13 [10-16] cmH2O) (P < 0.001). Median MP was also higher in sepsis and pneumonia patients. ΔP, as opposed to MP, was associated with ICU mortality in sepsis and pneumonia patients. Conclusions: The intensity of ventilation differed between patients with sepsis or pneumonia and patients receiving ventilation for any other reason; ΔP was associated with higher mortality in sepsis and pneumonia patients. Registration: This post hoc analysis was not registered; the individual studies that were merged into the used database were registered at clinicaltrials.gov: NCT01268410 (ERICC), NCT02010073 (LUNG SAFE), NCT01868321 (PRoVENT), and NCT03188770 (PRoVENT–iMiC).
KW - Critical care
KW - Driving pressure
KW - Mechanical power
KW - Pneumonia
KW - Ventilation intensity
KW - sepsis
UR - http://www.scopus.com/inward/record.url?scp=85185485854&partnerID=8YFLogxK
U2 - 10.1016/j.jcrc.2024.154531
DO - 10.1016/j.jcrc.2024.154531
M3 - Article
C2 - 38341938
SN - 0883-9441
VL - 81
JO - Journal of Critical Care
JF - Journal of Critical Care
M1 - 154531
ER -