TY - JOUR
T1 - Early mortality in prophylactic implantable cardioverter-defibrillator recipients: development and validation of a clinical risk score
AU - Kraaier, Karin
AU - Scholten, Marcoen F.
AU - Tijssen, Jan G. P.
AU - Theuns, Dominic A. M. J.
AU - Jordaens, Luc J. L. M.
AU - Wilde, Arthur A. M.
AU - van Dessel, Pascal F. H. M.
PY - 2014
Y1 - 2014
N2 - To reduce sudden cardiac death, implantable cardioverter-defibrillators (ICDs) are indicated in patients with ischaemic and non-ischaemic dilated cardiomyopathy and a left ventricular ejection fraction (LVEF) ≤35%. Current guidelines do not recommend device therapy in patients with a life expectancy <1 year since benefit in these patients is low. In this study, we evaluated the incidence and predictors of early mortality ( <1 year after implantation) in a consecutive primary prevention population. Analysis was performed on a prediction and validation cohort. The primary endpoint was all-cause mortality at 1 year. The prediction cohort comprised 861 prophylactic ICD recipients with ischaemic cardiomyopathy or dilated cardiomyopathy from the Academic Medical Center (Amsterdam) and Thorax Center Twente (Enschede). Detailed clinical data were collected. After multivariate analysis, a risk score was developed based on age ≥75 years, LVEF ≤ 20%, history of atrial fibrillation, and estimated glomerular filtration rate (eGFR) ≤30 mL/min/1.73 m(2). Using these predictors, a low (≤1 factor), intermediate (2 factors), and high (≥3 factors) risk group could be identified with 1-year mortality of, respectively, 3.4, 10.9, and 38.9% (P <0.01). Afterwards, the risk score was validated in 706 primary prevention patients from the Erasmus Medical Center (Rotterdam). One-year mortality was, respectively, 2.5, 13.2, and 46.3% (all P <0.01). A simple risk score based on age, LVEF, eGFR, and atrial fibrillation can identify patients at low, intermediate, and high risk for early mortality after ICD implantation. This may be helpful in the risk assessment of ICD candidates
AB - To reduce sudden cardiac death, implantable cardioverter-defibrillators (ICDs) are indicated in patients with ischaemic and non-ischaemic dilated cardiomyopathy and a left ventricular ejection fraction (LVEF) ≤35%. Current guidelines do not recommend device therapy in patients with a life expectancy <1 year since benefit in these patients is low. In this study, we evaluated the incidence and predictors of early mortality ( <1 year after implantation) in a consecutive primary prevention population. Analysis was performed on a prediction and validation cohort. The primary endpoint was all-cause mortality at 1 year. The prediction cohort comprised 861 prophylactic ICD recipients with ischaemic cardiomyopathy or dilated cardiomyopathy from the Academic Medical Center (Amsterdam) and Thorax Center Twente (Enschede). Detailed clinical data were collected. After multivariate analysis, a risk score was developed based on age ≥75 years, LVEF ≤ 20%, history of atrial fibrillation, and estimated glomerular filtration rate (eGFR) ≤30 mL/min/1.73 m(2). Using these predictors, a low (≤1 factor), intermediate (2 factors), and high (≥3 factors) risk group could be identified with 1-year mortality of, respectively, 3.4, 10.9, and 38.9% (P <0.01). Afterwards, the risk score was validated in 706 primary prevention patients from the Erasmus Medical Center (Rotterdam). One-year mortality was, respectively, 2.5, 13.2, and 46.3% (all P <0.01). A simple risk score based on age, LVEF, eGFR, and atrial fibrillation can identify patients at low, intermediate, and high risk for early mortality after ICD implantation. This may be helpful in the risk assessment of ICD candidates
U2 - https://doi.org/10.1093/europace/eut223
DO - https://doi.org/10.1093/europace/eut223
M3 - Article
C2 - 23918791
SN - 1099-5129
VL - 16
SP - 40
EP - 46
JO - Europace : European pacing, arrhythmias, and cardiac electrophysiology
JF - Europace : European pacing, arrhythmias, and cardiac electrophysiology
IS - 1
ER -