TY - JOUR
T1 - Embolus location affects the sensitivity of a rapid quantitative D-dimer assay in the diagnosis of pulmonary embolism
AU - de Monyé, Wouter
AU - Sanson, Bernd-Jan
AU - Mac Gillavry, Melvin R.
AU - Pattynama, Peter M. T.
AU - Büller, Harry R.
AU - van den Berg-Huysmans, Annette A.
AU - Huisman, Menno V.
PY - 2002
Y1 - 2002
N2 - D-dimer blood tests have been suggested to rule out pulmonary embolism. Despite evidence of the safety of withholding anticoagulant treatment in patients with suspected pulmonary embolism and a normal D-dimer assay result, clinicians remain reluctant to use a D-dimer assay as a sole diagnostic test. This prospective study in 314 consecutive inpatients and outpatients investigates the relation between the diagnostic accuracy of D-dimer plasma concentration and pulmonary embolus location. Plasma D-dimer levels were measured using a quantitative immunoturbidimetric method. A strict protocol of ventilation-perfuslon scintigraphy, pulmonary angiography, and spiral computed tomography was used to arrive at a final diagnosis and to assess the largest pulmonary artery in which embolus was visible. The influence of embolus location on the diagnostic accuracy was evaluated using the Kruskal-Wallis test and receiver operator characteristics (ROC) analysis. There was a strong correlation between plasma D-dimer concentration and embolus location (Kruskal-Wallis, p <0.001). Thus, the assay showed greater accuracy in excluding segmental or larger emboli (sensitivity = 93%) than subsegmental emboli (sensitivity = 50%). D-dimer concentration and the accuracy of D-dimer assays are clearly dependent on embolus location and smaller, subsegmental emboli may be missed when D-dimer assays are used as a sole test to exclude pulmonary embolism
AB - D-dimer blood tests have been suggested to rule out pulmonary embolism. Despite evidence of the safety of withholding anticoagulant treatment in patients with suspected pulmonary embolism and a normal D-dimer assay result, clinicians remain reluctant to use a D-dimer assay as a sole diagnostic test. This prospective study in 314 consecutive inpatients and outpatients investigates the relation between the diagnostic accuracy of D-dimer plasma concentration and pulmonary embolus location. Plasma D-dimer levels were measured using a quantitative immunoturbidimetric method. A strict protocol of ventilation-perfuslon scintigraphy, pulmonary angiography, and spiral computed tomography was used to arrive at a final diagnosis and to assess the largest pulmonary artery in which embolus was visible. The influence of embolus location on the diagnostic accuracy was evaluated using the Kruskal-Wallis test and receiver operator characteristics (ROC) analysis. There was a strong correlation between plasma D-dimer concentration and embolus location (Kruskal-Wallis, p <0.001). Thus, the assay showed greater accuracy in excluding segmental or larger emboli (sensitivity = 93%) than subsegmental emboli (sensitivity = 50%). D-dimer concentration and the accuracy of D-dimer assays are clearly dependent on embolus location and smaller, subsegmental emboli may be missed when D-dimer assays are used as a sole test to exclude pulmonary embolism
U2 - https://doi.org/10.1164/ajrccm.165.3.2104099
DO - https://doi.org/10.1164/ajrccm.165.3.2104099
M3 - Article
C2 - 11818319
SN - 1073-449X
VL - 165
SP - 345
EP - 348
JO - American journal of respiratory and critical care medicine
JF - American journal of respiratory and critical care medicine
IS - 3
ER -