TY - JOUR
T1 - In vivo detection of hemorrhage in human atherosclerotic plaques with magnetic resonance imaging
AU - Cappendijk, Vincent C.
AU - Cleutjens, Kitty B. J. M.
AU - Heeneman, Sylvia
AU - Schurink, Geert Willem H.
AU - Welten, Rob J. Th J.
AU - Kessels, Alfons G. H.
AU - van Suylen, Robert J.
AU - Daemen, Mat J. A. P.
AU - van Engelshoven, Jos M. A.
AU - Kooi, M. Eline
PY - 2004
Y1 - 2004
N2 - To investigate the performance of high-resolution T1-weighted (T1w) turbo field echo (TFE) magnetic resonance imaging (MRI) for the identification of the high-risk component intraplaque hemorrhage, which is described in the literature as a troublesome component to detect. An MRI scan was performed preoperatively on 11 patients who underwent carotid endarterectomy because of symptomatic carotid disease with a stenosis larger than 70%. A commonly used double inversion recovery (DIR) T1w turbo spin echo (TSE) served as the T1w control for the T1w TFE pulse sequence. The MR images were matched slice by slice with histology, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the MR images were calculated. Additionally, two readers, who were blinded for the histological results, independently assessed the MR slices concerning the presence of intraplaque hemorrhage. More than 80% of the histological proven intraplaque hemorrhage could be detected using the TFE sequence with a high interobserver agreement (Kappa = 0.73). The TFE sequence proved to be superior to the TSE sequence concerning SNR and CNR, but also in the qualitative detection of intraplaque hemorrhage. The false positive TFE results contained fibrous tissue and were all located outside the main plaque area. The present study shows that in vivo high-resolution T1w TFE MRI can identify the high-risk component intraplaque hemorrhage with a high detection rate in patients with symptomatic carotid disease. Larger clinical trials are warranted to investigate whether this technique can identify patients at risk for an ischemic attack
AB - To investigate the performance of high-resolution T1-weighted (T1w) turbo field echo (TFE) magnetic resonance imaging (MRI) for the identification of the high-risk component intraplaque hemorrhage, which is described in the literature as a troublesome component to detect. An MRI scan was performed preoperatively on 11 patients who underwent carotid endarterectomy because of symptomatic carotid disease with a stenosis larger than 70%. A commonly used double inversion recovery (DIR) T1w turbo spin echo (TSE) served as the T1w control for the T1w TFE pulse sequence. The MR images were matched slice by slice with histology, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the MR images were calculated. Additionally, two readers, who were blinded for the histological results, independently assessed the MR slices concerning the presence of intraplaque hemorrhage. More than 80% of the histological proven intraplaque hemorrhage could be detected using the TFE sequence with a high interobserver agreement (Kappa = 0.73). The TFE sequence proved to be superior to the TSE sequence concerning SNR and CNR, but also in the qualitative detection of intraplaque hemorrhage. The false positive TFE results contained fibrous tissue and were all located outside the main plaque area. The present study shows that in vivo high-resolution T1w TFE MRI can identify the high-risk component intraplaque hemorrhage with a high detection rate in patients with symptomatic carotid disease. Larger clinical trials are warranted to investigate whether this technique can identify patients at risk for an ischemic attack
U2 - https://doi.org/10.1002/jmri.20060
DO - https://doi.org/10.1002/jmri.20060
M3 - Article
C2 - 15221815
SN - 1053-1807
VL - 20
SP - 105
EP - 110
JO - Journal of magnetic resonance imaging
JF - Journal of magnetic resonance imaging
IS - 1
ER -