Lowering iodinated contrast concentration in infrainguinal endovascular interventions: a three-armed randomized controlled non-inferiority trial

Sjoerd Jens, Sanne M. Schreuder, Diederik W. de Boo, Lukas C. van Dijk, Hans van Overhagen, Shandra Bipat, Mark J. W. Koelemay, Jim A. Reekers

Research output: Contribution to journalArticleAcademicpeer-review

8 Citations (Scopus)

Abstract

To determine the influence of lowering iodinated contrast concentration on confidence of interventional radiologists in diagnosing and treating lesions during endovascular interventions in patients with symptomatic peripheral arterial disease (PAD). A randomized controlled non-inferiority trial was performed in 60 patients. Intervention was performed with contrast concentrations (in mg of iodine per mL, mgI/mL) of 300 (standard), 240, or 140 mgI/mL. Primary outcome was confidence (score 0-100 %) of radiologists in diagnosing and treating arterial lesions. Secondary outcomes were procedural iodine load and image quality (i.e. non-diagnostic, limited, diagnostic, exemplary). Median confidence scores in diagnosing lesions were 100 % (range 81-100 %) for the 300 group (n = 21), 100 % (range 82-100 %) for the 240 group (n = 19), and 100 % (range 91-100 %) for the 140 group (n = 20) (both p = 1.00 compared to the 300 group). Median scores for treating lesions in the 240 and 140 groups, 100 % (range 79-100 %, p = 0.40), and 100 % (range 63-100 %, p = 0.25), respectively, were not lower compared to the 300 group (median 100 %, range 78-100 %). Procedural iodine load was lower in the 240 (24.3 ± 7.6 g, p = 0.022) and 140 groups (17.8 ± 5.6 g, p  < 0.001) compared to the 300 group (29.7 ± 6.3 g). Image quality was diagnostic for all groups. Using iodine contrast of 140 mgI/mL for diagnosis and interventions in PAD patients significantly reduces administered iodine load without compromising image quality. Future use of lower iodine dose is recommended. • Lower iodinated contrast concentration during endovascular intervention does not decrease radiologist's confidence. • Image quality of standardized angiographies remains diagnostic using 140 mgI/mL iodinated contrast concentration. • Iodine load during intervention can be decreased by >40 % when using 140 mgI/mL. • Implementing the use of a lower iodinated contrast concentration will reduce the costs of the procedure
Original languageEnglish
Pages (from-to)2446-2454
JournalEuropean Radiology
Volume26
Issue number8
DOIs
Publication statusPublished - 2016

Cite this