TY - JOUR
T1 - Modifiable risk factors for permanent pacemaker after transcatheter aortic valve implantation
T2 - CONDUCT registry
AU - Rudolph, Tanja
AU - Droppa, Michal
AU - Baan, Jan
AU - Nielsen, Niels-Erik
AU - Baranowski, Jacek
AU - Hachaturyan, Violetta
AU - Kurucova, Jana
AU - Hack, Luis
AU - Bramlage, Peter
AU - Geisler, Tobias
N1 - Funding Information: This work was funded by a research grant from Edwards Lifesciences (Nyon, Switzerland) to the Institute for Pharmacology and Preventive Medicine (IPPMed, Cloppenburg, Germany). Publisher Copyright: © 2023 BMJ Publishing Group. All rights reserved.
PY - 2023/2/7
Y1 - 2023/2/7
N2 - Objective The onset of new conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is still a relevant adverse event. The main objective of this registry was to identify modifiable procedural risk factors for an improved outcome (lower rate of PPI) after TAVI in patients at high risk of PPI. Methods Patients from four European centres receiving a balloon-expandable TAVI (Edwards SAPIEN 3/3 Ultra) and considered at high risk of PPI (pre-existing conduction disturbance, heavily calcified left ventricular outflow tract or short membranous septum) were prospectively enrolled into registry. Results A total of 300 patients were included: 42 (14.0%) required PPI after TAVI and 258 (86.0%) did not. Patients with PPI had a longer intensive care unit plus intermediate care stay (65.7 vs 16.3 hours, p<0.001), general ward care stay (6.9 vs 5.3 days, p=0.004) and later discharge (8.6 vs 5.0 days, p<0.001). Of the baseline variables, only pre-existing right bundle branch block at baseline (OR 6.8, 95% CI 2.5 to 18.1) was significantly associated with PPI in the multivariable analysis. Among procedure-related variables, oversizing had the highest impact on the rate of PPI: higher than manufacturer-recommended sizing, mean area oversizing as well as the use of the 29 mm valve (OR 3.4, 95% CI 1.4 to 8.5, p=0.008) all were significantly associated with PPI. Rates were higher with the SAPIEN 3 (16.1%) vs SAPIEN 3 Ultra (8.5%), although not statistically significant but potentially associated with valve sizing. Implantation depth and postdelivery balloon dilatation also tended to affect PPI rates but without a statistical significance. Conclusion Valve oversizing is a strong procedure-related risk factor for PPI following TAVI. The clinical impact of the valve type (SAPIEN 3), implantation depth, and postdelivery balloon dilatation did not reach significance and may reflect already refined procedures in the participating centres, giving attention to these avoidable risk factors. Trial registration number NCT03497611.
AB - Objective The onset of new conduction abnormalities requiring permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation (TAVI) is still a relevant adverse event. The main objective of this registry was to identify modifiable procedural risk factors for an improved outcome (lower rate of PPI) after TAVI in patients at high risk of PPI. Methods Patients from four European centres receiving a balloon-expandable TAVI (Edwards SAPIEN 3/3 Ultra) and considered at high risk of PPI (pre-existing conduction disturbance, heavily calcified left ventricular outflow tract or short membranous septum) were prospectively enrolled into registry. Results A total of 300 patients were included: 42 (14.0%) required PPI after TAVI and 258 (86.0%) did not. Patients with PPI had a longer intensive care unit plus intermediate care stay (65.7 vs 16.3 hours, p<0.001), general ward care stay (6.9 vs 5.3 days, p=0.004) and later discharge (8.6 vs 5.0 days, p<0.001). Of the baseline variables, only pre-existing right bundle branch block at baseline (OR 6.8, 95% CI 2.5 to 18.1) was significantly associated with PPI in the multivariable analysis. Among procedure-related variables, oversizing had the highest impact on the rate of PPI: higher than manufacturer-recommended sizing, mean area oversizing as well as the use of the 29 mm valve (OR 3.4, 95% CI 1.4 to 8.5, p=0.008) all were significantly associated with PPI. Rates were higher with the SAPIEN 3 (16.1%) vs SAPIEN 3 Ultra (8.5%), although not statistically significant but potentially associated with valve sizing. Implantation depth and postdelivery balloon dilatation also tended to affect PPI rates but without a statistical significance. Conclusion Valve oversizing is a strong procedure-related risk factor for PPI following TAVI. The clinical impact of the valve type (SAPIEN 3), implantation depth, and postdelivery balloon dilatation did not reach significance and may reflect already refined procedures in the participating centres, giving attention to these avoidable risk factors. Trial registration number NCT03497611.
KW - aortic valve stenosis
KW - pacemaker, artificial
KW - transcatheter aortic valve replacement
UR - http://www.scopus.com/inward/record.url?scp=85148417749&partnerID=8YFLogxK
U2 - https://doi.org/10.1136/openhrt-2022-002191
DO - https://doi.org/10.1136/openhrt-2022-002191
M3 - Article
C2 - 36750275
SN - 2398-595X
VL - 10
JO - Open Heart
JF - Open Heart
IS - 1
M1 - e002191
ER -