Near-infrared spectroscopy in the routine diagnostic work-up of patients with leg ischaemia

D. T. Ubbink, B. Koopman

Research output: Contribution to journalArticleAcademicpeer-review

45 Citations (Scopus)

Abstract

OBJECTIVE: To examine the reproducibility and clinical applicability of near-infrared spectroscopy (NIRS) in patients with leg ischaemia. DESIGN: Prospective comparative diagnostic study. MATERIALS AND METHODS: Routinely measured peripheral blood pressure and microcirculatory parameters were compared with tissue oxygen saturation (TsO(2)) measurements using a new NIRS device on the calf muscle and the foot. Healthy subjects (n=20) and patients in different stages of leg ischaemia (n=45) were investigated at rest and after provocation: a treadmill test, arterial occlusion and a change in posture. Healthy volunteers were used as an age-matched reference population. RESULTS: Reproducibility of the NIRS was excellent (intraclass correlation coefficient at rest was 0.91 (95% confidence interval: 80-99). Resting TsO(2) (65%) in healthy controls did not differ significantly from that in patients (Fontaine 2: 66%; F3/4: 68%). After exercise, a significant reduction in TsO(2) was observed only in patients: Fontaine 1: 60%; Fontaine 2: 21%, Fontaine 3/4: 29%. The ankle/brachial index after exercise showed a good correlation (R=0.73) with TsO(2) at the end of the treadmill test. No correlation between NIRS and other micro- or macrocirculatory parameters was found. CONCLUSION: NIRS is a very reproducible tool to assess tissue oxygen saturation, but is not useful for the routine work-up of patients with leg ischaemia
Original languageEnglish
Pages (from-to)394-400
JournalEuropean Journal of Vascular and Endovascular Surgery
Volume31
Issue number4
DOIs
Publication statusPublished - 2006

Cite this