Optical Monte Carlo modeling of a true port wine stain anatomy

J.K. Barton, T.J. Pfefer, A.J. Welch, D.J. Smithies, J.S. Nelson, M.J.C. van Gemert

Research output: Contribution to journalArticleAcademicpeer-review

33 Citations (Scopus)

Abstract

A unique Monte Carlo program capable of accommodating an arbitrarily complex geometry was used to determine the energy deposition in a true port wine stain anatomy. Serial histologic sections taken from a biopsy of a dark red, laser therapy resistant stain were digitized and used to create the program input for simulation at wavelengths of 532 and 585 nm. At both wavelengths, the greatest energy deposition occurred in the superficial blood vessels, and subsequently decreased with depth as the laser beam was attenuated. However, more energy was deposited in the epidermis and superficial blood vessels at 532 nm than at 585 nm
Original languageUndefined/Unknown
Pages (from-to)391-396
JournalOptics express
Volume2
Issue number9
DOIs
Publication statusPublished - 1998

Keywords

  • AMC wi-buiten

Cite this