Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry

Ben J. Mijnheer, Patrick González, Igor Olaciregui-Ruiz, Roel A. Rozendaal, Marcel van Herk, Anton Mans

Research output: Contribution to journalArticleAcademicpeer-review

62 Citations (Scopus)

Abstract

To assess the usefulness of electronic portal imaging device (EPID)-based 3-dimensional (3D) transit dosimetry in a radiation therapy department by analyzing a large set of dose verification results. In our institution, routine in vivo dose verification of all treatments is performed by means of 3D transit dosimetry using amorphous silicon EPIDs. The total 3D dose distribution is reconstructed using a back-projection algorithm and compared with the planned dose distribution using 3D gamma evaluation. Dose reconstruction and gamma evaluation software runs automatically in our clinic, and analysis results are (almost) immediately available. If a deviation exceeds our alert criteria, manual inspection is required. If necessary, additional phantom measurements are performed to separate patient-related errors from planning or delivery errors. Three-dimensional transit dosimetry results were analyzed per treatment site between 2012 and 2014 and the origin of the deviations was assessed. In total, 4689 of 15,076 plans (31%) exceeded the alert criteria between 2012 and 2014. These alerts were patient-related and attributable to limitations of our back-projection and dose calculation algorithm or to external sources. Clinically relevant deviations were detected for approximately 1 of 430 patient treatments. Most of these errors were because of anatomical changes or deviations from the routine clinical procedure and would not have been detected by pretreatment verification. Although cone beam computed tomography scans yielded information about anatomical changes, their effect on the dose delivery was assessed quantitatively by means of 3D in vivo dosimetry. EPID-based transit dosimetry is a fast and efficient dose verification technique. It provides more useful information and is less time-consuming than pretreatment verification measurements of intensity modulated radiation therapy and volumetric modulated arc therapy. Large-scale implementation of 3D transit dosimetry is therefore a powerful method to guarantee safe dose delivery during radiation therapy
Original languageEnglish
Pages (from-to)e679-e687
JournalPractical radiation oncology
Volume5
Issue number6
DOIs
Publication statusPublished - 2015

Cite this