T1 - Performance and logistical challenges of alternative HIV-1 virological monitoring options in a clinical setting of Harare, Zimbabwe
AU - Ondoa, Pascale
AU - Shamu, Tinei
AU - Bronze, Michelle
AU - Wellington, Maureen
AU - Boender, Tamara Sonia
AU - Manting, Corry
AU - Steegen, Kim
AU - Luethy, Rudi
AU - Rinke de Wit, Tobias
PY - 2014
Y1 - 2014
N2 - We evaluated a low-cost virological failure assay (VFA) on plasma and dried blood spot (DBS) specimens from HIV-1 infected patients attending an HIV clinic in Harare. The results were compared to the performance of the ultrasensitive heat-denatured p24 assay (p24). The COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0, served as the gold standard. Using a cutoff of 5,000 copies/mL, the plasma VFA had a sensitivity of 94.5% and specificity of 92.7% and was largely superior to the VFA on DBS (sensitivity = 61.9%; specificity = 99.0%) or to the p24 (sensitivity = 54.3%; specificity = 82.3%) when tested on 302 HIV treated and untreated patients. However, among the 202 long-term ART-exposed patients, the sensitivity of the VFA decreased to 72.7% and to 35.7% using a threshold of 5,000 and 1,000 RNA copies/mL, respectively. We show that the VFA (either on plasma or on DBS) and the p24 are not reliable to monitor long-term treated, HIV-1 infected patients. Moreover, achieving acceptable assay sensitivity using DBS proved technically difficult in a less-experienced laboratory. Importantly, the high level of virological suppression (93%) indicated that quality care focused on treatment adherence limits virological failure even when PCR-based viral load monitoring is not available
AB - We evaluated a low-cost virological failure assay (VFA) on plasma and dried blood spot (DBS) specimens from HIV-1 infected patients attending an HIV clinic in Harare. The results were compared to the performance of the ultrasensitive heat-denatured p24 assay (p24). The COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0, served as the gold standard. Using a cutoff of 5,000 copies/mL, the plasma VFA had a sensitivity of 94.5% and specificity of 92.7% and was largely superior to the VFA on DBS (sensitivity = 61.9%; specificity = 99.0%) or to the p24 (sensitivity = 54.3%; specificity = 82.3%) when tested on 302 HIV treated and untreated patients. However, among the 202 long-term ART-exposed patients, the sensitivity of the VFA decreased to 72.7% and to 35.7% using a threshold of 5,000 and 1,000 RNA copies/mL, respectively. We show that the VFA (either on plasma or on DBS) and the p24 are not reliable to monitor long-term treated, HIV-1 infected patients. Moreover, achieving acceptable assay sensitivity using DBS proved technically difficult in a less-experienced laboratory. Importantly, the high level of virological suppression (93%) indicated that quality care focused on treatment adherence limits virological failure even when PCR-based viral load monitoring is not available
U2 - https://doi.org/10.1155/2014/102598
DO - https://doi.org/10.1155/2014/102598
M3 - Article
C2 - 25025031
SN - 2314-6133
VL - 2014
SP - 102598
JO - Biomed research international
JF - Biomed research international
ER -