Preparation, radiochemical purity control and stability of 99mTc-mertiatide (Mag-3)

F.J. van Hemert, H. van Lenthe, K.J.M. Schimmel, B.L.F. van Eck-Smit

Research output: Contribution to journalArticleAcademicpeer-review

9 Citations (Scopus)

Abstract

BACKGROUND: Scintigraphic image analysis of 99mTc-mertiatide (Mag-3, mercaptoacetyltriglycine) clearance provides the determination of the blood flow, the tubular transit time and the excretion as well from both kidneys. Radiopharmaceutical routine recommends a radiochemical purity control before administration of the product to a patient. The main objective of this study is to develop a Mag-3 labeling procedure that fits better than the previous one in our daily routine production of radiopharmaceuticals. METHODS: Increasing proportions of 99mTc-Mag-3 were measured during the heating and cooling steps of the Mag-3 labeling procedure. HPLC analysis was used to confirm the results of a rapid radiochemical quality control assay on standard ITLC-SG paper. RESULTS: The reconstitution time takes 20-25 minutes from the harvest of pertechnetate to a ready-for-use calibrated patient syringe. The HPLC profile of 99mTc-Mag-3 including its minor impurities remains unchanged for 24-48 hours after reconstitution. CONCLUSIONS: The application of a programmable Peltier-directed device for heating/cooling provides a better control of the temperature course. The procedure proposed fully meets the labeling criteria recommended by the supplier and can be performed with a minimum of attention within a time-span that we formerly needed for solely the radiochemical purity control assay. Moreover, 99mTc-Mag-3 prepared in this way seems to be considerably more stable than mentioned in the manufacturer's instructions
Original languageUndefined/Unknown
Pages (from-to)345-349
JournalAnnals of nuclear medicine
Volume19
Issue number4
DOIs
Publication statusPublished - 2005

Keywords

  • AMC overig

Cite this