TY - JOUR
T1 - Role of cardiac 123I-mIBG imaging in predicting arrhythmic events in stable chronic heart failure patients with an ICD
AU - de Vincentis, Giuseppe
AU - Frantellizzi, Viviana
AU - Fedele, Francesco
AU - Farcomeni, Alessio
AU - Scarparo, Paola
AU - Salvi, Nicolò
AU - Fegatelli, Danilo Alunni
AU - Mancone, Massimo
AU - Verschure, Derk O.
AU - Verberne, Hein J.
PY - 2019/8
Y1 - 2019/8
N2 - Background: Despite therapeutic improvement, the prognosis of chronic heart failure (CHF) remains unfavorable partly due to arrhythmia and sudden cardiac death (SCD). This prospective study evaluated myocardial 123I-meta-iodobenzylguanidine (123I-mIBG) scintigraphy as a predictor of arrhythmic events (AE) in CHF patients. Methods: 170 CHF patients referred for implantable cardioverter-defibrillator (ICD) implantation for both primary and secondary prevention were enrolled. All patients underwent planar and SPECT imaging. Early and late heart-to-mediastinum (H/M) ratio, 123I-mIBG washout (WO), early and late summed SPECT scores were calculated The primary endpoint was an AE: sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate ICD therapy or SCD. The secondary endpoint was appropriate ICD therapy. Results: During a median follow-up of 23.3 months, 69 patients experienced an AE. Early summed score (ESS) was the only independent predictor of AE [HR 1.023 (1.003-1.043)]. Focussing on only patients with an ICD for primary prevention, ESS was the only independent predictor of AE [HR 1.028 (1.007-1.050)]. 123I-mIBG-derived parameters failed to be independent predictors of appropriate ICD therapy. However there was a “bell-shaped” relation between 123I-mIBG scintigraphy-derived parameters and AE and appropriate ICD therapy, i.e., those with intermediate 123I-mIBG abnormalities tended to be at higher risk of events. Conclusion: Although SPECT 123I-mIBG scintigraphy was associated with AE in CHF patients with ICD implantation for primary and secondary prevention, no association was found between 123I-mIBG scintigraphy-derived parameters and appropriate ICD therapy.
AB - Background: Despite therapeutic improvement, the prognosis of chronic heart failure (CHF) remains unfavorable partly due to arrhythmia and sudden cardiac death (SCD). This prospective study evaluated myocardial 123I-meta-iodobenzylguanidine (123I-mIBG) scintigraphy as a predictor of arrhythmic events (AE) in CHF patients. Methods: 170 CHF patients referred for implantable cardioverter-defibrillator (ICD) implantation for both primary and secondary prevention were enrolled. All patients underwent planar and SPECT imaging. Early and late heart-to-mediastinum (H/M) ratio, 123I-mIBG washout (WO), early and late summed SPECT scores were calculated The primary endpoint was an AE: sustained ventricular tachycardia, resuscitated cardiac arrest, appropriate ICD therapy or SCD. The secondary endpoint was appropriate ICD therapy. Results: During a median follow-up of 23.3 months, 69 patients experienced an AE. Early summed score (ESS) was the only independent predictor of AE [HR 1.023 (1.003-1.043)]. Focussing on only patients with an ICD for primary prevention, ESS was the only independent predictor of AE [HR 1.028 (1.007-1.050)]. 123I-mIBG-derived parameters failed to be independent predictors of appropriate ICD therapy. However there was a “bell-shaped” relation between 123I-mIBG scintigraphy-derived parameters and AE and appropriate ICD therapy, i.e., those with intermediate 123I-mIBG abnormalities tended to be at higher risk of events. Conclusion: Although SPECT 123I-mIBG scintigraphy was associated with AE in CHF patients with ICD implantation for primary and secondary prevention, no association was found between 123I-mIBG scintigraphy-derived parameters and appropriate ICD therapy.
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85044463431&origin=inward
UR - https://www.ncbi.nlm.nih.gov/pubmed/29594915
U2 - https://doi.org/10.1007/s12350-018-1258-z
DO - https://doi.org/10.1007/s12350-018-1258-z
M3 - Article
C2 - 29594915
SN - 1071-3581
VL - 26
SP - 1188
EP - 1196
JO - Journal of Nuclear Cardiology
JF - Journal of Nuclear Cardiology
IS - 4
ER -