TY - JOUR
T1 - Split bolus technique in polytrauma: a prospective study on scan protocols for trauma analysis
AU - Beenen, Ludo F. M.
AU - Sierink, Joanne C.
AU - Kolkman, Saskia
AU - Nio, C. Yung
AU - Saltzherr, Teun Peter
AU - Dijkgraaf, Marcel G. W.
AU - Goslings, J. Carel
PY - 2015
Y1 - 2015
N2 - For the evaluation of severely injured trauma patients a variety of total body computed tomography (CT) scanning protocols exist. Frequently multiple pass protocols are used. A split bolus contrast protocol can reduce the number of passes through the body, and thereby radiation exposure, in this relatively young and vitally threatened population. To evaluate three protocols for single pass total body scanning in 64-slice multidetector CT (MDCT) on optimal image quality. Three total body CT protocols were prospectively evaluated in three series of 10 consecutive trauma patients. In Group A unenhanced brain and cervical spine CT was followed by chest-abdomen-pelvis CT in portovenous phase after repositioning of the arms. Group B underwent brain CT followed without arm repositioning by a one-volume contrast CT from skull base to the pubic symphysis. Group C was identical to Group A, but the torso was scanned with a split bolus technique. Three radiologists independently evaluated protocol quality scores (5-point Likert scale), parenchymal and vascular enhancement and artifacts. Overall image quality was good (4.10) in Group A, more than satisfactory (3.38) in Group B, and nearly excellent (4.75) in Group C (P < 0.001). Interfering artifacts were mostly reported in Group B in the liver and spleen. In single pass total body CT scanning a split bolus technique reached the highest overall image quality compared to conventional total body CT and one-volume contrast CT
AB - For the evaluation of severely injured trauma patients a variety of total body computed tomography (CT) scanning protocols exist. Frequently multiple pass protocols are used. A split bolus contrast protocol can reduce the number of passes through the body, and thereby radiation exposure, in this relatively young and vitally threatened population. To evaluate three protocols for single pass total body scanning in 64-slice multidetector CT (MDCT) on optimal image quality. Three total body CT protocols were prospectively evaluated in three series of 10 consecutive trauma patients. In Group A unenhanced brain and cervical spine CT was followed by chest-abdomen-pelvis CT in portovenous phase after repositioning of the arms. Group B underwent brain CT followed without arm repositioning by a one-volume contrast CT from skull base to the pubic symphysis. Group C was identical to Group A, but the torso was scanned with a split bolus technique. Three radiologists independently evaluated protocol quality scores (5-point Likert scale), parenchymal and vascular enhancement and artifacts. Overall image quality was good (4.10) in Group A, more than satisfactory (3.38) in Group B, and nearly excellent (4.75) in Group C (P < 0.001). Interfering artifacts were mostly reported in Group B in the liver and spleen. In single pass total body CT scanning a split bolus technique reached the highest overall image quality compared to conventional total body CT and one-volume contrast CT
U2 - https://doi.org/10.1177/0284185114539319
DO - https://doi.org/10.1177/0284185114539319
M3 - Article
C2 - 25033993
SN - 0284-1851
VL - 56
SP - 873
EP - 880
JO - Acta radiologica (Stockholm, Sweden
JF - Acta radiologica (Stockholm, Sweden
IS - 7
ER -