TY - JOUR
T1 - Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adenosylhomocysteine in plasma
AU - Gellekink, Henkjan
AU - Van Oppenraaij-Emmerzaal, Dinny
AU - Van Rooij, Arno
AU - Struys, Eduard A.
AU - Heijer, Martin Den
AU - Blom, Henk J.
PY - 2005/8
Y1 - 2005/8
N2 - Background: It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet). Methods: We used stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry (LC-ESI-MS/MS) to measure AdoMet and AdoHcy in plasma. Acetic acid was added to prevent AdoMet degradation. Solid-phase extraction (SPE) columns containing phenylboronic acid were used to bind AdoMet, AdoHcy, and their internal standards and for sample cleanup. An HPLC C18 column directly coupled to the LC-MS/MS was used for separation and detection. Results: In plasma samples, the interassay CVs for AdoMet and AdoHcy were 3.9% and 8.3%, and the intraassay CVs were 4.2% and 6.7%, respectively. Mean recoveries were 94.5% for AdoMet and 96.8% for AdoHcy. The quantification limits were 2.0 and 1.0 nmol/L for AdoMet and AdoHcy, respectively. Immediate acidification of the plasma samples with acetic acid prevented the observed AdoMet degradation. In a group of controls (mean plasma total Hcy, 11.2 μmol/L), plasma AdoMet and AdoHcy were 94.5 and 12.3 nmol/L, respectively. Conclusions: Stable-isotope dilution LC-ESI-MS/MS allows sensitive and rapid measurement of AdoMet and AdoHcy. The SPE columns enable simple cleanup, and no metabolite derivatization is needed. The instability of AdoMet is a serious problem and can be prevented easily by immediate acidification of samples.
AB - Background: It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet). Methods: We used stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry (LC-ESI-MS/MS) to measure AdoMet and AdoHcy in plasma. Acetic acid was added to prevent AdoMet degradation. Solid-phase extraction (SPE) columns containing phenylboronic acid were used to bind AdoMet, AdoHcy, and their internal standards and for sample cleanup. An HPLC C18 column directly coupled to the LC-MS/MS was used for separation and detection. Results: In plasma samples, the interassay CVs for AdoMet and AdoHcy were 3.9% and 8.3%, and the intraassay CVs were 4.2% and 6.7%, respectively. Mean recoveries were 94.5% for AdoMet and 96.8% for AdoHcy. The quantification limits were 2.0 and 1.0 nmol/L for AdoMet and AdoHcy, respectively. Immediate acidification of the plasma samples with acetic acid prevented the observed AdoMet degradation. In a group of controls (mean plasma total Hcy, 11.2 μmol/L), plasma AdoMet and AdoHcy were 94.5 and 12.3 nmol/L, respectively. Conclusions: Stable-isotope dilution LC-ESI-MS/MS allows sensitive and rapid measurement of AdoMet and AdoHcy. The SPE columns enable simple cleanup, and no metabolite derivatization is needed. The instability of AdoMet is a serious problem and can be prevented easily by immediate acidification of samples.
UR - http://www.scopus.com/inward/record.url?scp=23044449221&partnerID=8YFLogxK
U2 - https://doi.org/10.1373/clinchem.2004.046995
DO - https://doi.org/10.1373/clinchem.2004.046995
M3 - Article
C2 - 15919880
SN - 0009-9147
VL - 51
SP - 1487
EP - 1492
JO - Clinical Chemistry
JF - Clinical Chemistry
IS - 8
ER -