Stenosis detection in forearm hemodialysis arteriovenous fistulae by multiphase contrast-enhanced magnetic resonance angiography: preliminary experience

R. Nils Planken, Jan H. M. Tordoir, Ruben Dammers, Michiel W. de Haan, T. Khiam Oei, Freek M. van der Sande, Jos M. A. van Engelshoven, Tim Leiner

Research output: Contribution to journalArticleAcademicpeer-review

30 Citations (Scopus)

Abstract

To assess the feasibility and accuracy of multiphase contrast-enhanced magnetic resonance angiography (CE-MRA) in patients with dysfunctioning hemodialysis arteriovenous fistulae (AVF), using digital subtraction angiography (DSA) as the standard of reference. Fifteen patients with dysfunctioning AVF (eight radiocephalic and seven graft AVF) underwent CE-MRA. Dysfunction was defined as a flow decline of more than 25% in 1 month measured by dilutional flow measurements. CE-MRA was performed during injection of 35 mL of gadolinium-DTPA. The CE-MRA sequence consisted of a time-resolved series of 10 scans, each lasting approximately 10 seconds. The technical parameters were TR/TE/FA/voxel = 5.4/1.6/40/3.1 mm(3), and a rectangular surface reception coil was used. All patients were scheduled to undergo DSA at which an intervention was carried out when a stenosis >or=50% was seen. Two observers, unaware of each other's findings and the findings at DSA, quantified the number and degree of stenosis in the failing AVF. Image quality for CE-MRA and DSA was scored on a 3-point scale. The diagnostic performance of CE-MRA was analyzed with receiver-operator characteristic (ROC) analysis. CE-MRA and DSA examinations were performed without side effects in all 15 patients. Image quality was scored significantly better on CE-MRA (observer 1: CE-MRA, 2.0; DSA, 1.3; P =.001; observer 2: CE-MRA, 2.0; DSA, 1.4; P =.002). Interobserver agreement for detection of >or=50% stenosis was 0.81 (95% confidence interval (CI) = 0.71-0.92) for CE-MRA and 0.69 (95% CI = 0.55-0.84) for DSA. ROC analysis revealed a mean area under the curve of 0.78. On the patient level, at the >or=50% threshold, mean sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were 100% (95% CI = 69%-100%), 10% (95% CI = 0%-78%), 70% (95% CI = 38%-92%), and 100% (95% CI = 50%-100%), respectively. At the >or=75% threshold, mean sensitivity, specificity, PPV, and NPV were 75% (95% CI = 20%-99%), 78% (95% CI = 39%-98%), 55% (95% CI = 12%-96%), and 89% (95% CI = 52%-100%), respectively. CE-MRA is a useful diagnostic tool for detecting stenoses in flow-declined hemodialysis AVF prior to interventional DSA
Original languageEnglish
Pages (from-to)54-64
JournalJournal of magnetic resonance imaging
Volume17
Issue number1
DOIs
Publication statusPublished - 2003
Externally publishedYes

Cite this