TY - JOUR
T1 - Test-retest reliability of heart rate variability and respiration rate at rest and during light physical activity in normal subjects
AU - Guijt, Alida M.
AU - Sluiter, Judith K.
AU - Frings-Dresen, Monique H. W.
PY - 2007
Y1 - 2007
N2 - BACKGROUND: A variable that remains stable over repeated measurements (in stable conditions) is ideal for tracking modifications of the clinical state. The aim of the present study is to examine test-retest reliability of time-domain heart rate variability and respiration rate measurements using a portable device on normal subjects during rest and light physical activity. METHODS: Twenty-six normal subjects [18 females and 8 males aged 28 +/- 6 years and 34 +/- 12 years (mean +/- SD), respectively] underwent two measurements for time-domain heart rate variability (SDNN and RMSSD) and respiration rate, with 7 days in between. Measurements took place under three conditions: lying down in a laboratory, cycling in a laboratory and sleeping in an ambulatory surrounding. Reliability was assessed statistically by calculating intra-class correlation coefficients (ICC). RESULTS: Reliability was found to be good to excellent for both time-domain heart rate variability (SDNN: ICC values between 0.74 and 0.85, RMSSD: ICC values between 0.75 and 0.98) and for respiration rate (ICC values between 0.77 and 0.96). CONCLUSIONS: Both time-domain heart rate variability and respiration rate can be reliably assessed. However, we advise reliability research in a clinical setting before using the device for tracking modifications in a clinical state
AB - BACKGROUND: A variable that remains stable over repeated measurements (in stable conditions) is ideal for tracking modifications of the clinical state. The aim of the present study is to examine test-retest reliability of time-domain heart rate variability and respiration rate measurements using a portable device on normal subjects during rest and light physical activity. METHODS: Twenty-six normal subjects [18 females and 8 males aged 28 +/- 6 years and 34 +/- 12 years (mean +/- SD), respectively] underwent two measurements for time-domain heart rate variability (SDNN and RMSSD) and respiration rate, with 7 days in between. Measurements took place under three conditions: lying down in a laboratory, cycling in a laboratory and sleeping in an ambulatory surrounding. Reliability was assessed statistically by calculating intra-class correlation coefficients (ICC). RESULTS: Reliability was found to be good to excellent for both time-domain heart rate variability (SDNN: ICC values between 0.74 and 0.85, RMSSD: ICC values between 0.75 and 0.98) and for respiration rate (ICC values between 0.77 and 0.96). CONCLUSIONS: Both time-domain heart rate variability and respiration rate can be reliably assessed. However, we advise reliability research in a clinical setting before using the device for tracking modifications in a clinical state
U2 - https://doi.org/10.1016/j.arcmed.2006.07.009
DO - https://doi.org/10.1016/j.arcmed.2006.07.009
M3 - Article
C2 - 17174734
SN - 0188-4409
VL - 38
SP - 113
EP - 120
JO - Archives of medical research
JF - Archives of medical research
IS - 1
ER -