TY - JOUR
T1 - The impact of acquisition time of planar cardiac (123)I-MIBG imaging on the late heart to mediastinum ratio
AU - Dimitriu-Leen, Aukelien C.
AU - Gimelli, Alessia
AU - Al Younis, Imad
AU - Veltman, Caroline E.
AU - Verberne, Hein J.
AU - Wolterbeek, Ron
AU - Zandbergen-Harlaar, Silvia
AU - Bax, Jeroen J.
AU - Scholte, Arthur J. H. A.
PY - 2016
Y1 - 2016
N2 - The aim of this study was to investigate whether performing the late cardiac (123)I-metaiodobenzylguanidine (MIBG) scan earlier than 4 h post-injection (p.i.) has relevant impact on the late heart to mediastinum ratio (H/M ratio) in patients with heart failure (HF). Forty-nine patients with HF (median left ventricular ejection fraction of 31 %, 51 % ischaemic HF) referred for cardiac (123)I-MIBG scintigraphy were scanned at 15 min (early) p.i. and at 1, 2, 3 and 4 h (late) p.i. of (123)I-MIBG. Late H/M ratios were calculated and evaluated using a linear mixed model with the mean late H/M ratio at 4 h p.i. as a reference. A difference in late H/M ratios of more than 0.10 between the different acquisition times in comparison with the late H/M ratio at 4 h p.i. was considered as clinically relevant. Statistically significant mean differences were observed between the late H/M ratios at 1, 2 and 3 h p.i. compared with the late H/M ratio at 4 h p.i. (0.09, 0.05 and 0.02, respectively). However, the mean differences did not exceed the cut-off value of 0.10. On an individual patient level, compared to the late H/M ratio at 4 h p.i., the late H/M ratios at 1, 2 and 3 h p.i. differed more than 0.10 in 24 (50 %), 9 (19 %) and 2 (4 %) patients, respectively. Variation in acquisition time of (123)I-MIBG between 2 and 4 h p.i. does not lead to a clinically significant change in the late H/M ratio. An earlier acquisition time seems to be justified and may warrant a more time-efficient cardiac (123)I-MIBG imaging protocol
AB - The aim of this study was to investigate whether performing the late cardiac (123)I-metaiodobenzylguanidine (MIBG) scan earlier than 4 h post-injection (p.i.) has relevant impact on the late heart to mediastinum ratio (H/M ratio) in patients with heart failure (HF). Forty-nine patients with HF (median left ventricular ejection fraction of 31 %, 51 % ischaemic HF) referred for cardiac (123)I-MIBG scintigraphy were scanned at 15 min (early) p.i. and at 1, 2, 3 and 4 h (late) p.i. of (123)I-MIBG. Late H/M ratios were calculated and evaluated using a linear mixed model with the mean late H/M ratio at 4 h p.i. as a reference. A difference in late H/M ratios of more than 0.10 between the different acquisition times in comparison with the late H/M ratio at 4 h p.i. was considered as clinically relevant. Statistically significant mean differences were observed between the late H/M ratios at 1, 2 and 3 h p.i. compared with the late H/M ratio at 4 h p.i. (0.09, 0.05 and 0.02, respectively). However, the mean differences did not exceed the cut-off value of 0.10. On an individual patient level, compared to the late H/M ratio at 4 h p.i., the late H/M ratios at 1, 2 and 3 h p.i. differed more than 0.10 in 24 (50 %), 9 (19 %) and 2 (4 %) patients, respectively. Variation in acquisition time of (123)I-MIBG between 2 and 4 h p.i. does not lead to a clinically significant change in the late H/M ratio. An earlier acquisition time seems to be justified and may warrant a more time-efficient cardiac (123)I-MIBG imaging protocol
U2 - https://doi.org/10.1007/s00259-015-3220-5
DO - https://doi.org/10.1007/s00259-015-3220-5
M3 - Article
C2 - 26515715
SN - 1619-7070
VL - 43
SP - 326
EP - 332
JO - European journal of nuclear medicine and molecular imaging
JF - European journal of nuclear medicine and molecular imaging
IS - 2
ER -