The use of a newly designed nonabsorbable polymeric stent in reconstructing the vas deferens: a feasibility study in New Zealand white rabbits

Eric J. Vrijhof, Adriaan de Bruine, Aeilko H. Zwinderman, August A. B. Lycklama à Nijeholt, Leo H. Koole

Research output: Contribution to journalArticleAcademicpeer-review

8 Citations (Scopus)

Abstract

OBJECTIVES: To investigate the use of a newly designed stent in the reconstruction of the vas deferens. MATERIALS AND METHODS: In 26 New Zealand White rabbits, 13 conventional one-layer microscopic reconstructions were compared with 13 stented reconstructions of the vas deferens. The newly designed nonabsorbable polymeric stent was shaped to facilitate the rejoining of the two loose ends of the vas deferens, using a central ridge to prevent migration. Semen was collected before and after surgery, using an artificial vaginal system (26 samples before and 115 after surgery). The individual and average total sperm count, motility and progressive motile sperm density (PMSD), were compared after surgery for both groups. After the final semen analysis, rabbits were killed and patency was assessed histologically at the site of the anastomosis. RESULTS: After an initial decline the mean total sperm count increased in both groups. The increase was significantly larger (P = 0.05) in the stented rabbits. The mean motility and PMSD showed no significant differences between both groups (P = 0.11 and 0.71, respectively). Histological examination of the anastomosed area showed partial obstruction (>50% narrowing of the original lumen) in five of the 13 conventionally treated rabbits, with no strictures in the stented group. Despite the narrowing in the conventional group the patency rates were not affected. The mean (range) operating time for the conventional and stented groups was 132 (99-168) and 98 (62-113) min, respectively (P < 0.001). CONCLUSIONS: The total sperm counts, motility and PMSD showed no or little difference after surgery between the conventional and stented rabbits. The stented reconstruction was easy, had no secondary stricturing and reduced the operating time
Original languageEnglish
Pages (from-to)1081-1085
JournalBJU international
Volume95
Issue number7
DOIs
Publication statusPublished - 2005

Cite this