T1 - Therapy From a Novel Substernal Lead: The ASD2 Study
AU - Boersma, Lucas V. A.
AU - Merkely, B. la
AU - Neuzil, Petr
AU - Crozier, Ian G.
AU - Akula, Devender N.
AU - Timmers, Liesbeth
AU - Kalarus, Zbigniew
AU - Sherfesee, Lou
AU - DeGroot, Paul J.
AU - Thompson, Amy E.
AU - Lexcen, Daniel R.
AU - Knight, Bradley P.
PY - 2019
Y1 - 2019
N2 - Objectives: The ASD2 (Acute Extravascular Defibrillation, Pacing, and Electrogram) study evaluated the ability to adequately sense, pace, and defibrillate patients with a novel implantable cardioverter-defibrillator (ICD) lead implanted in the substernal space. Background: Subcutaneous ICDs are an alternative to a transvenous defibrillator system when transvenous implantation is not possible or desired. An alternative extravascular system placing a lead under the sternum has the potential to reduce defibrillation energy and the ability to deliver pacing therapies. Methods: An investigational lead was inserted into the substernal space via a minimally invasive subxiphoid access, and a cutaneous defibrillation patch or subcutaneous active can emulator was placed on the left mid-axillary line. Pacing thresholds and extracardiac stimulation were evaluated. Up to 2 episodes of ventricular fibrillation were induced to test defibrillation efficacy. Results: The substernal lead was implanted in 79 patients, with a median implantation time of 12.0 ± 9.0 min. Ventricular pacing was successful in at least 1 vector in 76 of 78 patients (97.4%), and 72 of 78 (92.3%) patients had capture in ≥1 vector with no extracardiac stimulation. A 30-J shock successfully terminated 104 of 128 episodes (81.3%) of ventricular fibrillation in 69 patients. There were 7 adverse events in 6 patients causally (n = 5) or possibly (n = 2) related to the ASD2 procedure. Conclusions: The ASD2 study demonstrated the ability to pace, sense, and defibrillate using a lead designed specifically for the substernal space.
AB - Objectives: The ASD2 (Acute Extravascular Defibrillation, Pacing, and Electrogram) study evaluated the ability to adequately sense, pace, and defibrillate patients with a novel implantable cardioverter-defibrillator (ICD) lead implanted in the substernal space. Background: Subcutaneous ICDs are an alternative to a transvenous defibrillator system when transvenous implantation is not possible or desired. An alternative extravascular system placing a lead under the sternum has the potential to reduce defibrillation energy and the ability to deliver pacing therapies. Methods: An investigational lead was inserted into the substernal space via a minimally invasive subxiphoid access, and a cutaneous defibrillation patch or subcutaneous active can emulator was placed on the left mid-axillary line. Pacing thresholds and extracardiac stimulation were evaluated. Up to 2 episodes of ventricular fibrillation were induced to test defibrillation efficacy. Results: The substernal lead was implanted in 79 patients, with a median implantation time of 12.0 ± 9.0 min. Ventricular pacing was successful in at least 1 vector in 76 of 78 patients (97.4%), and 72 of 78 (92.3%) patients had capture in ≥1 vector with no extracardiac stimulation. A 30-J shock successfully terminated 104 of 128 episodes (81.3%) of ventricular fibrillation in 69 patients. There were 7 adverse events in 6 patients causally (n = 5) or possibly (n = 2) related to the ASD2 procedure. Conclusions: The ASD2 study demonstrated the ability to pace, sense, and defibrillate using a lead designed specifically for the substernal space.
UR - https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85061124512&origin=inward
U2 - https://doi.org/10.1016/j.jacep.2018.11.003
DO - https://doi.org/10.1016/j.jacep.2018.11.003
M3 - Article
C2 - 30784689
SN - 2405-500X
VL - 5
SP - 186
EP - 196
JO - JACC. Clinical electrophysiology
JF - JACC. Clinical electrophysiology
IS - 2
ER -