TY - JOUR
T1 - Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry
AU - Romano, Mauro
AU - Frank, Derk
AU - Cocchieri, Riccardo
AU - Jagielak, Dariusz
AU - Bonaros, Nikolaos
AU - Aiello, Marco
AU - Lapeze, Joel
AU - Laine, Mika
AU - Chocron, Sidney
AU - Muir, Douglas
AU - Eichinger, Walter
AU - Thielmann, Matthias
AU - Labrousse, Louis
AU - Arne Rein, Kjell
AU - Verhoye, Jean-Philippe
AU - Gerosa, Gino
AU - Baumbach, Hardy
AU - Deutsch, Cornelia
AU - Bramlage, Peter
AU - Thoenes, Martin
AU - Bapat, Vinayak
PY - 2017
Y1 - 2017
N2 - Transaortic (TAo) access for transcatheter aortic valve implantation (TAVI) is an alternative to the conventional transfemoral or transapical routes. Data comparing the characteristics and outcomes of TAo-TAVI using the SAPIEN XT and SAPIEN 3 heart valves are scarce. The objective of the current analysis was to provide such information. ROUTE is an international, prospective, observational registry. Patients with severe calcific aortic stenosis scheduled for TAo-TAVI with an Edwards SAPIEN XT or a SAPIEN 3 heart valve were consecutively enrolled at 22 centres across Europe between February 2013 and February 2015. Periprocedural, in-hospital and 30-day complication rates were assessed. Of the 301 patients included, 126 (41.9%) received a SAPIEN 3 and 175 (58.1%) a SAPIEN XT. The SAPIEN 3 was associated with shorter procedure time (101 ± 35 vs 111 ± 40 min; P = 0.031) and a lower quantity of contrast agent used (87 ± 43 vs 112 ± 50 ml; P < 0.001). Balloon dilation was performed less often before (68.0% vs 78.3%; P = 0.045) and after implantation (13.6% vs 30.1%; P = 0.001). No statistically significant differences between the valve types were documented for overall (4.1% SAPIEN 3 vs 7.6% SAPIEN XT; P = 0.21), TAVI-related (0.8% vs 4.7%; P = 0.084) and cardiovascular mortality (2.4% vs 5.9%; P = 0.158). Major vascular complications were less frequent (0.8% vs 5.3%; P = 0.049), and there was a lower rate of moderate-to-severe paravalvular regurgitation (0.8% vs 5.1%; P = 0.050) in the SAPIEN 3 group. Both the SAPIEN XT and SAPIEN 3 were safely implanted via the TAo route, though the SAPIEN 3 may be associated with a higher procedural success rate and improved prognosis. NCT01991431
AB - Transaortic (TAo) access for transcatheter aortic valve implantation (TAVI) is an alternative to the conventional transfemoral or transapical routes. Data comparing the characteristics and outcomes of TAo-TAVI using the SAPIEN XT and SAPIEN 3 heart valves are scarce. The objective of the current analysis was to provide such information. ROUTE is an international, prospective, observational registry. Patients with severe calcific aortic stenosis scheduled for TAo-TAVI with an Edwards SAPIEN XT or a SAPIEN 3 heart valve were consecutively enrolled at 22 centres across Europe between February 2013 and February 2015. Periprocedural, in-hospital and 30-day complication rates were assessed. Of the 301 patients included, 126 (41.9%) received a SAPIEN 3 and 175 (58.1%) a SAPIEN XT. The SAPIEN 3 was associated with shorter procedure time (101 ± 35 vs 111 ± 40 min; P = 0.031) and a lower quantity of contrast agent used (87 ± 43 vs 112 ± 50 ml; P < 0.001). Balloon dilation was performed less often before (68.0% vs 78.3%; P = 0.045) and after implantation (13.6% vs 30.1%; P = 0.001). No statistically significant differences between the valve types were documented for overall (4.1% SAPIEN 3 vs 7.6% SAPIEN XT; P = 0.21), TAVI-related (0.8% vs 4.7%; P = 0.084) and cardiovascular mortality (2.4% vs 5.9%; P = 0.158). Major vascular complications were less frequent (0.8% vs 5.3%; P = 0.049), and there was a lower rate of moderate-to-severe paravalvular regurgitation (0.8% vs 5.1%; P = 0.050) in the SAPIEN 3 group. Both the SAPIEN XT and SAPIEN 3 were safely implanted via the TAo route, though the SAPIEN 3 may be associated with a higher procedural success rate and improved prognosis. NCT01991431
U2 - https://doi.org/10.1093/icvts/ivx159
DO - https://doi.org/10.1093/icvts/ivx159
M3 - Article
C2 - 28582580
SN - 1569-9293
VL - 25
SP - 757
EP - 764
JO - Interactive cardiovascular and thoracic surgery
JF - Interactive cardiovascular and thoracic surgery
IS - 5