TY - JOUR
T1 - Tumor volume changes during stereotactic ablative radiotherapy for adrenal gland metastases under MRI guidance
AU - Giraud, Nicolas
AU - Schneiders, Famke L.
AU - van Sornsen de Koste, John R.
AU - Palacios, Miguel A.
AU - Senan, Suresh
N1 - Publisher Copyright: © 2023 The Author(s)
PY - 2023/9/1
Y1 - 2023/9/1
N2 - Purpose: Gross tumor volume (GTV) changes during stereotactic ablative radiotherapy (SABR) for adrenal tumors are not well characterized. We studied treatment-induced GTV changes during, and after, 5-fraction MR-guided SABR on a 0.35 T unit. Methods and Materials: Details of patients treated for adrenal metastases using 5-fraction adaptive MR-SABR were accessed. GTV changes between simulation and first fraction (ΔSF1) and all fractions were recorded. Wilcoxon paired tests were used for intrapatient comparisons. Logistic and linear regression models were used for features associated with dichotomous and continuous variables, respectively. Results: Once-daily fractions of 8 Gy or 10 Gy were delivered to 70 adrenal metastases. Median simulation-F1 interval was 13 days; F1-F5 interval was 13 days. Median baseline GTVs at simulation and F1 were 26.6 and 27.2 cc, respectively (p < 0.001). Mean ΔSF1 was + 9.1% (2.9 cc) relative to simulation; 47% of GTVs decreased in volume at F5 versus F1. GTV variations of ≥ 20% occurred in 59% treatments at some point between simulation to end SABR, and these did not correlate with baseline tumor characteristics. At a median follow-up of 20.3 months, a radiological complete response (CR) was seen in 23% of 64 evaluable patients. CR was associated with baseline GTV (p = 0.03) and ΔF1F5 (p = 0.03). Local relapses were seen in 6%. Conclusion: Frequent changes in adrenal GTVs during 5-fraction SABR delivery support the use of on-couch adaptive replanning. The likelihood of a radiological CR correlates with the baseline GTV and intra-treatment GTV decline.
AB - Purpose: Gross tumor volume (GTV) changes during stereotactic ablative radiotherapy (SABR) for adrenal tumors are not well characterized. We studied treatment-induced GTV changes during, and after, 5-fraction MR-guided SABR on a 0.35 T unit. Methods and Materials: Details of patients treated for adrenal metastases using 5-fraction adaptive MR-SABR were accessed. GTV changes between simulation and first fraction (ΔSF1) and all fractions were recorded. Wilcoxon paired tests were used for intrapatient comparisons. Logistic and linear regression models were used for features associated with dichotomous and continuous variables, respectively. Results: Once-daily fractions of 8 Gy or 10 Gy were delivered to 70 adrenal metastases. Median simulation-F1 interval was 13 days; F1-F5 interval was 13 days. Median baseline GTVs at simulation and F1 were 26.6 and 27.2 cc, respectively (p < 0.001). Mean ΔSF1 was + 9.1% (2.9 cc) relative to simulation; 47% of GTVs decreased in volume at F5 versus F1. GTV variations of ≥ 20% occurred in 59% treatments at some point between simulation to end SABR, and these did not correlate with baseline tumor characteristics. At a median follow-up of 20.3 months, a radiological complete response (CR) was seen in 23% of 64 evaluable patients. CR was associated with baseline GTV (p = 0.03) and ΔF1F5 (p = 0.03). Local relapses were seen in 6%. Conclusion: Frequent changes in adrenal GTVs during 5-fraction SABR delivery support the use of on-couch adaptive replanning. The likelihood of a radiological CR correlates with the baseline GTV and intra-treatment GTV decline.
KW - Adrenal metastases
KW - IGRT
KW - MR-guided radiotherapy
KW - Radiomics
KW - SABR
UR - http://www.scopus.com/inward/record.url?scp=85162905513&partnerID=8YFLogxK
U2 - https://doi.org/10.1016/j.radonc.2023.109749
DO - https://doi.org/10.1016/j.radonc.2023.109749
M3 - Article
C2 - 37330058
SN - 0167-8140
VL - 186
JO - Radiotherapy and oncology
JF - Radiotherapy and oncology
M1 - 109749
ER -