Research interests
Biomedical engineering in general. Main focus 2-D, 3-D and 4-D image acquisition and analysis:
- 3-D motion (4D) visualization and quantification of joints (mostly the wrist);
- Non-invasive detection of knee prosthesis loosening;
- Corrective osteotomy: Computer-assisted planning and navigation based on pre- and intraoperative 3-D imaging;
- Measurement of functional microcirculatory geometry and velocity distributions using automated image analysis;
- Syllectometry: Effect of aggregometer geometry in the assessment of red blood-cell shape recovery and aggregation;
- Ektacytometry and aggregometry with the Laser-assisted Optical Rotational Cell Analyzer (LORCA);
- 3D Cryomicrotome imaging.
specialisation
Medical imaging: 2-D, 3-D and 4-D medical imaging; surgical planning/navigation, ektacytometry, syllectometry, rheoscopy, cryosectioning.
Collaborations and top research areas from the last five years
Projects
- 1 Active
-
Streekstra G.J.: Medical Imaging
ten Berg, P., Dvinskikh, N., de Roo, M., Wellenberg, R., Streekstra, G., Marquering, H., Dobbe, J. G. G. & van der Meer, J.
1/01/2010 → …
Project: Research
Research output
-
Comparison of an oblique single cut rotation osteotomy with a novel 3D computer-assisted oblique double cut alignment approach
Dobbe, J. G. G., Kloen, P., Strackee, S. D. & Streekstra, G. J., 1 Dec 2021, In: Scientific reports. 11, 1, 14731.Research output: Contribution to journal › Article › Academic › peer-review
Open Access3 Citations (Scopus) -
Evaluation of a Quantitative Method for Carpal Motion Analysis Using Clinical 3-D and 4-D CT Protocols
Dobbe, J. G. G., de Roo, M. G. A., Visschers, J. C., Strackee, S. D. & Streekstra, G. J., 1 Apr 2019, In: IEEE Transactions on Medical Imaging. 38, 4, p. 1048-1057Research output: Contribution to journal › Article › Academic › peer-review
30 Citations (Scopus) -
Minimizing the translation error in the application of an oblique single-cut rotation osteotomy: Where to cut?
Dobbe, J. G. G., Strackee, S. D. & Streekstra, G. J., 2018, In: IEEE transactions on bio-medical engineering. 65, 4, p. 821 - 827Research output: Contribution to journal › Article › Academic › peer-review
7 Citations (Scopus) -
Patient-specific plate for navigation and fixation of the distal radius: a case series
Dobbe, J. G. G., Peymani, A., Roos, H. A. L., Beerens, M., Streekstra, G. J. & Strackee, S. D., Mar 2021, In: International journal of computer assisted radiology and surgery. 16, 3, p. 515-524 10 p.Research output: Contribution to journal › Article › Academic › peer-review
Open Access12 Citations (Scopus) -
Measurement of the distribution of red blood cell deformability using an automated rheoscope
Dobbe, J. G. G., Streekstra, G. J., Hardeman, M. R., Ince, C. & Grimbergen, C. A., 2002, In: Cytometry. 50, 6, p. 313-325Research output: Contribution to journal › Article › Academic › peer-review
91 Citations (Scopus)
Datasets
-
DS_10.1177_1558944718793179 – Supplemental material for Surgical Management of Madelung Deformity: A Systematic Review
Peymani, A. (Creator), Johnson, A. R. (Creator), Dowlatshahi, A. S. (Contributor), Dobbe, J. G. G. (Creator), Lin, S. J. (Creator), Upton, J. (Creator), Streekstra, G. (Creator) & Strackee, S. D. (Creator), SAGE Journals, 2018
DOI: 10.25384/sage.6967043.v1, https://sage.figshare.com/articles/DS_10_1177_1558944718793179_Supplemental_material_for_Surgical_Management_of_Madelung_Deformity_A_Systematic_Review/6967043/1 and one more link, https://sage.figshare.com/articles/DS_10_1177_1558944718793179_Supplemental_material_for_Surgical_Management_of_Madelung_Deformity_A_Systematic_Review/6967043 (show fewer)
Dataset