Associations between positive end-expiratory pressure and outcome of patients without ARDS at onset of ventilation: a systematic review and meta-analysis of randomized controlled trials

Ary Serpa Neto, Roberto Rabello Filho, Thomas Cherpanath, Rogier Determann, Dave A. Dongelmans, Frederique Paulus, Pieter Roel Tuinman, Paolo Pelosi, Marcelo Gama de Abreu, Marcus J. Schultz, R. Rabello, Prove Network Investigators

Research output: Contribution to journalArticleAcademicpeer-review

25 Citations (Scopus)

Abstract

The aim of this investigation was to compare ventilation at different levels of positive end-expiratory pressure (PEEP) with regard to clinical important outcomes of intensive care unit (ICU) patients without acute respiratory distress syndrome (ARDS) at onset of ventilation. Meta-analysis of randomized controlled trials (RCTs) comparing a lower level of PEEP with a higher level of PEEP was performed. The primary outcome was in-hospital mortality. Twenty-one RCTs (1393 patients) were eligible. PEEP ranged from 0 to 10 cmH2O and from 5 to 30 cmH2O in the lower PEEP and the higher PEEP arms of included RCTs, respectively. In-hospital mortality was not different between the two PEEP arms in seven RCTs (risk ratio [RR] 0.87; 95% confidence interval [CI] 0.62-1.21; I (2) = 26%, low quality of evidence [QoE]), as was duration of mechanical ventilation in three RCTs (standardized mean difference [SMD] 0.68; 95% CI -0.24 to 1.61; I (2) = 82%, very low QoE). PaO2/FiO2 was higher in the higher PEEP arms in five RCTs (SMD 0.72; 95% CI 0.10-1.35; I (2) = 86%, very low QoE). Development of ARDS and the occurrence of hypoxemia (2 RCTs) were lower in the higher PEEP arms in four RCTs and two RCTs, respectively (RR 0.43; 95% CI 0.21-0.91; I (2) = 56%, low QoE; RR 0.42; 95%-CI 0.19-0.92; I (2) = 19%, low QoE). There was no association between the level of PEEP and any hemodynamic parameter (four RCTs). Ventilation with higher levels of PEEP in ICU patients without ARDS at onset of ventilation was not associated with lower in-hospital mortality or shorter duration of ventilation, but with a lower incidence of ARDS and hypoxemia, as well as higher PaO2/FiO2. These findings should be interpreted with caution, as heterogeneity was moderate to high, the QoE was low to very low, and the available studies prevented us from addressing the effects of moderate levels of PEEP
Original languageEnglish
Article number109
Pages (from-to)109
Number of pages5
JournalAnnals of intensive care
Volume6
Issue number1
DOIs
Publication statusPublished - 2016

Cite this