TY - JOUR
T1 - Development and Validation of a Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) Assay for the Determination of Total and Unbound Ciprofloxacin Concentrations in Human Plasma
AU - de Vroom, Suzanne L.
AU - Pistorius, Marcel C. M.
AU - Bijleveld, Yuma A.
AU - Geerlings, Suzanne E.
AU - Mathôt, Ron A. A.
AU - van Hest, Reinier M.
AU - Jager, Nynke G. L.
N1 - Publisher Copyright: Copyright © 2022 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2022/8/1
Y1 - 2022/8/1
N2 - BACKGROUND: Although unbound ciprofloxacin is responsible for antibacterial effects, assays measuring the unbound drug plasma concentrations are scarce. This study aimed to develop and validate a rapid, reproducible, and sensitive liquid chromatography-tandem mass spectrometry assay for the determination of total and unbound ciprofloxacin plasma concentrations. METHODS: The determination of total ciprofloxacin concentrations required a 10 μL sample, while for unbound ciprofloxacin concentrations, it was 100 μL. Unbound ciprofloxacin was separated from protein-bound ciprofloxacin through ultrafiltration. A deuterated internal standard was used, and the sample preparation involved protein precipitation. The method was fully validated over a concentration range of 0.02-5.0 mg/L, according to the US Food and Drug Administration guidelines. In addition, its clinical application was demonstrated. RESULTS: The total run time was 1.5 minutes. For total ciprofloxacin plasma concentrations, the mean accuracy ranged from 94.5% to 105.0% across the validated range, the intraday imprecision was ≤7.6%, and the interday imprecision was ≤9.8%. For unbound ciprofloxacin plasma concentrations, the mean accuracy ranged from 92.8% to 102.1% across the validated range, the intraday imprecision was ≤7.0%, and the interday imprecision was ≤9.6%. Ciprofloxacin in plasma and ultrafiltrate remained stable for at least 96 hours at room temperature, at least 4 years at -80°C, and at least 3 freeze/thaw cycles (-80°C), with a minimum interval of 24 hours. CONCLUSIONS: The presented method is precise and accurate. It has been implemented in clinical care and research projects at a university hospital, permitting rapid determination of total and unbound ciprofloxacin.
AB - BACKGROUND: Although unbound ciprofloxacin is responsible for antibacterial effects, assays measuring the unbound drug plasma concentrations are scarce. This study aimed to develop and validate a rapid, reproducible, and sensitive liquid chromatography-tandem mass spectrometry assay for the determination of total and unbound ciprofloxacin plasma concentrations. METHODS: The determination of total ciprofloxacin concentrations required a 10 μL sample, while for unbound ciprofloxacin concentrations, it was 100 μL. Unbound ciprofloxacin was separated from protein-bound ciprofloxacin through ultrafiltration. A deuterated internal standard was used, and the sample preparation involved protein precipitation. The method was fully validated over a concentration range of 0.02-5.0 mg/L, according to the US Food and Drug Administration guidelines. In addition, its clinical application was demonstrated. RESULTS: The total run time was 1.5 minutes. For total ciprofloxacin plasma concentrations, the mean accuracy ranged from 94.5% to 105.0% across the validated range, the intraday imprecision was ≤7.6%, and the interday imprecision was ≤9.8%. For unbound ciprofloxacin plasma concentrations, the mean accuracy ranged from 92.8% to 102.1% across the validated range, the intraday imprecision was ≤7.0%, and the interday imprecision was ≤9.6%. Ciprofloxacin in plasma and ultrafiltrate remained stable for at least 96 hours at room temperature, at least 4 years at -80°C, and at least 3 freeze/thaw cycles (-80°C), with a minimum interval of 24 hours. CONCLUSIONS: The presented method is precise and accurate. It has been implemented in clinical care and research projects at a university hospital, permitting rapid determination of total and unbound ciprofloxacin.
UR - http://www.scopus.com/inward/record.url?scp=85134426563&partnerID=8YFLogxK
U2 - https://doi.org/10.1097/FTD.0000000000000969
DO - https://doi.org/10.1097/FTD.0000000000000969
M3 - Article
C2 - 35094000
SN - 0163-4356
VL - 44
SP - 552
EP - 557
JO - Therapeutic Drug Monitoring
JF - Therapeutic Drug Monitoring
IS - 4
ER -