TY - JOUR
T1 - Diagnostic Yield of ECG-Gated Cardiac CT in theAcute Phase of Ischemic Stroke vsTransthoracic Echocardiography
AU - Rinkel, Leon A.
AU - Guglielmi, Valeria
AU - Beemsterboer, Chiel F. P.
AU - Groeneveld, Nina-Suzanne
AU - Lobé, Nick H. J.
AU - Boekholdt, S. Matthijs
AU - Bouma, Berto J.
AU - Muller, Fenna F.
AU - Beenen, Ludo F. M.
AU - Marquering, Henk A.
AU - Majoie, Charles B. L. M.
AU - Roos, Yvo B. W. M.
AU - van Randen, Adrienne
AU - Planken, R. Nils
AU - Coutinho, Jonathan M.
N1 - Funding Information: V. Guglielmi received research grants from the Royal Netherlands Academy of Arts and Sciences (Van Leersum Grant), Foundation De Drie Lichten, Remmert Adriaan Laan Foundation, and AMC Young Talent Fund, all of which are nonprofit research foundations. Publisher Copyright: © American Academy of Neurology.
PY - 2022/10/4
Y1 - 2022/10/4
N2 - BACKGROUND AND OBJECTIVES: Guidelines recommend echocardiography to screen for structural sources of cardioembolism in patients with ischemic stroke. Cardiac CT is a promising alternative as a first-line screening method. We aimed to determine whether cardiac CT, acquired during the initial stroke imaging protocol, has a higher yield for detecting high-risk cardioaortic sources of embolism than transthoracic echocardiography (TTE). METHODS: We performed a prospective, single-center, observational cohort study and included consecutive adult patients with acute ischemic stroke who underwent ECG-gated cardiac CT during the initial stroke imaging protocol. Patients also underwent the routine stroke workup, including TTE. The main outcome was the proportion of patients with a predefined high-risk cardioaortic source of embolism on cardiac CT vs TTE in patients undergoing both investigations. RESULTS: Between May 2018 and November 2020, 774 patients with a suspected ischemic stroke underwent hyperacute cardiac CT. We excluded 228 patients with a diagnosis other than ischemic stroke and 94 because they did not provide informed consent. Therefore, 452 patients (59.3% male, median age 72) were included. The median additional scan time of cardiac CT was 6 (interquartile range 5-7) minutes with poor scan quality in only 3%. In total, 350 of the 452 patients (77.4%) underwent TTE, 99 of whom were performed in an outpatient setting. Reasons for not undergoing TTE were death (33, 7.3%) and TTE being too burdensome to perform in the outpatient setting (69, 15.3%). A high-risk cardioaortic source of embolism was detected in 40 of the 350 patients (11.4%) on CT, compared with 17 of the 350 (4.9%) on TTE (odds ratio 5.60, 95% CI 2.28-16.33). Cardiac thrombus was the most frequent finding (7.1% vs 0.6%). The diagnostic yield of cardiac CT in the full study population was 55 of the 452 (12.2%). Among the 175 patients with cryptogenic stroke after the routine workup, cardiac CT identified a cause of the stroke in 11 (6.3%). DISCUSSION: Cardiac CT acquired in the acute phase of ischemic stroke is technically feasible and has a superior diagnostic yield compared with TTE for the detection of high-risk sources of embolism. Cardiac CT may be considered as an alternative to TTE to screen for cardioembolism.
AB - BACKGROUND AND OBJECTIVES: Guidelines recommend echocardiography to screen for structural sources of cardioembolism in patients with ischemic stroke. Cardiac CT is a promising alternative as a first-line screening method. We aimed to determine whether cardiac CT, acquired during the initial stroke imaging protocol, has a higher yield for detecting high-risk cardioaortic sources of embolism than transthoracic echocardiography (TTE). METHODS: We performed a prospective, single-center, observational cohort study and included consecutive adult patients with acute ischemic stroke who underwent ECG-gated cardiac CT during the initial stroke imaging protocol. Patients also underwent the routine stroke workup, including TTE. The main outcome was the proportion of patients with a predefined high-risk cardioaortic source of embolism on cardiac CT vs TTE in patients undergoing both investigations. RESULTS: Between May 2018 and November 2020, 774 patients with a suspected ischemic stroke underwent hyperacute cardiac CT. We excluded 228 patients with a diagnosis other than ischemic stroke and 94 because they did not provide informed consent. Therefore, 452 patients (59.3% male, median age 72) were included. The median additional scan time of cardiac CT was 6 (interquartile range 5-7) minutes with poor scan quality in only 3%. In total, 350 of the 452 patients (77.4%) underwent TTE, 99 of whom were performed in an outpatient setting. Reasons for not undergoing TTE were death (33, 7.3%) and TTE being too burdensome to perform in the outpatient setting (69, 15.3%). A high-risk cardioaortic source of embolism was detected in 40 of the 350 patients (11.4%) on CT, compared with 17 of the 350 (4.9%) on TTE (odds ratio 5.60, 95% CI 2.28-16.33). Cardiac thrombus was the most frequent finding (7.1% vs 0.6%). The diagnostic yield of cardiac CT in the full study population was 55 of the 452 (12.2%). Among the 175 patients with cryptogenic stroke after the routine workup, cardiac CT identified a cause of the stroke in 11 (6.3%). DISCUSSION: Cardiac CT acquired in the acute phase of ischemic stroke is technically feasible and has a superior diagnostic yield compared with TTE for the detection of high-risk sources of embolism. Cardiac CT may be considered as an alternative to TTE to screen for cardioembolism.
UR - http://www.scopus.com/inward/record.url?scp=85139571447&partnerID=8YFLogxK
U2 - https://doi.org/10.1212/WNL.0000000000200995
DO - https://doi.org/10.1212/WNL.0000000000200995
M3 - Article
C2 - 35918169
SN - 0028-3878
VL - 99
SP - e1456-e1464
JO - Neurology
JF - Neurology
IS - 14
ER -