TY - JOUR
T1 - New Insights into the Effects of Chronic Kidney Failure and Dialysate Exposure on the Peritoneum
AU - Vlahu, Carmen A.
AU - Aten, Jan
AU - de Graaff, Marijke
AU - van Veen, Henk
AU - Everts, Vincent
AU - de Waart, Dirk R.
AU - Struijk, Dirk G.
AU - Krediet, Raymond T.
PY - 2016
Y1 - 2016
N2 - ♦ INTRODUCTION: Chronic uremia and the exposure to dialysis solutions during peritoneal dialysis (PD) induce peritoneal alterations. Using a long-term peritoneal exposure model, we compared the effects of chronic kidney failure (CKD) itself and exposure to either a 'conventional' or a 'biocompatible' dialysis solution on peritoneal morphology and function. ♦ METHODS: Wistar rats (Harlan, Zeist, the Netherlands) were grouped into: normal kidney function (NKF), CKD induced by 70% nephrectomy, CKD receiving daily peritoneal infusions with 3.86% glucose Dianeal (CKDD), or Physioneal (both solutions from Baxter Healthcare, Castlebar, Ireland) (CKDP). At 16 weeks, a peritoneal function test was performed, and histology, ultrastructure, and hydroxyproline content of peritoneal tissue were assessed. ♦ RESULTS: Comparing CKD with NKF, peritoneal transport rates were higher, mesothelial cells (MC) displayed increased number of microvilli, blood and lymph vasculature expanded, vascular basal lamina appeared thicker, with limited areas of duplication, and fibrosis had developed. All alterations, except lymphangiogenesis, were enhanced by exposure to both dialysis fluids. Distinct MC alterations were observed in CKDD and CKDP, the latter displaying prominent basolateral protrusions. In addition, CKDP was associated with a trend towards less fibrosis compared to CKDD. ♦ CONCLUSIONS: Chronic kidney failure itself induced peritoneal alterations, which were in part augmented by exposure to glucose-based dialysis solutions. Overall, the conventional and biocompatible solutions had similar long-term effects on the peritoneum. Importantly, the latter may attenuate the development of fibrosis
AB - ♦ INTRODUCTION: Chronic uremia and the exposure to dialysis solutions during peritoneal dialysis (PD) induce peritoneal alterations. Using a long-term peritoneal exposure model, we compared the effects of chronic kidney failure (CKD) itself and exposure to either a 'conventional' or a 'biocompatible' dialysis solution on peritoneal morphology and function. ♦ METHODS: Wistar rats (Harlan, Zeist, the Netherlands) were grouped into: normal kidney function (NKF), CKD induced by 70% nephrectomy, CKD receiving daily peritoneal infusions with 3.86% glucose Dianeal (CKDD), or Physioneal (both solutions from Baxter Healthcare, Castlebar, Ireland) (CKDP). At 16 weeks, a peritoneal function test was performed, and histology, ultrastructure, and hydroxyproline content of peritoneal tissue were assessed. ♦ RESULTS: Comparing CKD with NKF, peritoneal transport rates were higher, mesothelial cells (MC) displayed increased number of microvilli, blood and lymph vasculature expanded, vascular basal lamina appeared thicker, with limited areas of duplication, and fibrosis had developed. All alterations, except lymphangiogenesis, were enhanced by exposure to both dialysis fluids. Distinct MC alterations were observed in CKDD and CKDP, the latter displaying prominent basolateral protrusions. In addition, CKDP was associated with a trend towards less fibrosis compared to CKDD. ♦ CONCLUSIONS: Chronic kidney failure itself induced peritoneal alterations, which were in part augmented by exposure to glucose-based dialysis solutions. Overall, the conventional and biocompatible solutions had similar long-term effects on the peritoneum. Importantly, the latter may attenuate the development of fibrosis
U2 - https://doi.org/10.3747/pdi.2015.00204
DO - https://doi.org/10.3747/pdi.2015.00204
M3 - Article
C2 - 27147290
SN - 0896-8608
VL - 36
SP - 614
EP - 622
JO - Peritoneal Dialysis International
JF - Peritoneal Dialysis International
IS - 6
ER -