The standard peritoneal permeability analysis: a tool for the assessment of peritoneal permeability characteristics in CAPD patients

M. M. Pannekeet, A. L. Imholz, D. G. Struijk, G. C. Koomen, M. J. Langedijk, N. Schouten, R. de Waart, J. Hiralall, R. T. Krediet

Research output: Contribution to journalComment/Letter to the editorAcademic

169 Citations (Scopus)

Abstract

Peritoneal transport characteristics in CAPD patients are often assessed by the peritoneal equilibration test (PET), which uses a four hour dwell with glucose 2.27% dialysate. From the test, the dialysate/plasma ratio of creatinine (D/PCr), the dialysate/initial dialysate ratio of glucose (D/Do) and net ultrafiltration (NUF, drained minus instilled volume) are calculated. The standard peritoneal permeability analysis (SPA) is a modification and extension of the PET: glucose 1.36% dialysate is used, to which dextran 70 (1 g/liter) is added for the calculation of fluid kinetics. Mass transfer area coefficients (MTAC's) of low molecular weight solutes, clearances of proteins and the change in intraperitoneal volume (delta IPV) can be assessed. In this study the SPA was analyzed, and a comparison with the PET was made. A total number of 138 SPA's was analyzed in 86 different clinically stable patients. Normal values were calculated for both SPA and PET parameters in the same tests. Median (ranges) of comparable transport parameters from SPA and PET were: MTACCr, 10.4 ml/min (5.7 to 19.3); glucose absorption, 61% (35 to 87); delta IPV, 9.5 ml (-761 to 310); D/PCr, 0.76 (0.53 to 1.14); D/D0, 0.37 (0.13 to 0.56); NUF, -75 ml (-675 to 450). The agreement between SPA and PET was analyzed using the method of Bland and Altman. A fairly good agreement was present between NUF and delta IPV. Systematic errors were found when D/PCr and MTACCr were compared: D/P overestimated MTAC mainly in the low range, whereas in the high range values were underestimated. A similar pattern was seen for the transport parameters of glucose. In 40 patients negative net ultrafiltration was present, and possible reasons for this were assessed. In 9 patients no reason could be identified. It can be concluded that the SPA provides useful and extensive information on peritoneal transport parameters. Compared to the PET, the SPA has better discriminative power for the transport of glucose and creatinine
Original languageEnglish
Pages (from-to)866-875
JournalKidney International
Volume48
Issue number3
DOIs
Publication statusPublished - 1995

Cite this